![Panasonic RG-R811A Installation Instructions Manual Download Page 3](http://html.mh-extra.com/html/panasonic/rg-r811a/rg-r811a_installation-instructions-manual_266928003.webp)
Always disconnect the power source before working on or near the fan, motor or junction box.
Protect the supply wiring from sharp edges, oil, grease, hot surfaces,
chemicals or other objects.
Do not kink the supply wiring.
Not for use in cooking area. (Fig. A)
The special-purpose or dedicated parts, such as mounting fixtures,
must be used if such parts are provided.
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
Floor
45
°
45°
Cooking
equipment
Fig. A
(Cooking area)
Do not install above or
inside this area
Provide make up air for proper ventilation.
Do not connect multiple units in parallel. If two or more units are connected to one switch in parallel, the units
may not function.
Do not install the unit where ducts are configured as shown in below:
Bend close to duct adaptor
Squeezed duct
Successive bending
Excessive bending
Adaptor
These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to
have long operating life, high dynamic response, higher speed ranges and energy savings. The grille covering the fan
body is a spring-attached, quick removal type. A damper for preventing air counter flow is provided. The blower uses
a high-capacity sirocco fan developed to reduce the noise level.
These products are listed by UL under UL file No. E78414.
Unpack and carefully remove the unit from carton. Refer to the Supplied Accessories list to verify that all parts are
present.
3
GENERAL SAFETY INFORMATION (CONTINUED)
DESCRIPTION
UNPACKING