Secure the fan body to Flex-Z Fast™ bracket by using
2 self-drilling screws.
Plug connector into receptacle and secure fan body to
adaptor by using machine screw (M4X8).
2 self-drilling
screws
2
3
Machine screw
(M4X8)
Please take care when installing the machine screw
(Step 5) to avoid cross threading and to ensure that
the screw does not strip or come in contact with
Flex-Z Fast™ bracket.
Sealing
1
Adjust Pick-A-Flow™ switch. (Refer to explanation under
FEATURES). (Page 5)
2
Once fan body is mounted and secure, fill gap between flange
and ceiling with caulk or other sealant to prevent air leakage.
Joist
Joist
1
Install grille
Insert the mounting springs into the slot as
shown to mount grille to fan body.
1
Drywall
Mounting spring
Gloves
Grille
Insert the grille mounting spring on the wiring
side into the slot and insert the plug connector
into the housing of the lighting unit.
2
Before turning on the light, make sure the
connector is at the correct position. If not,
the lighting unit can’t work.
The claw of connector must latch onto the rib
completely.
Mount grille carefully so that the lead wire is
not pinched.
1
2
Mounting spring
Lighting unit
Drywall
INSTALLATION (RETROFIT) (CONTINUED)