background image

Model No. 

 

      

READ AND SAVE THESE INSTRUCTIONS

Thank you for purchasing this Panasonic product. 

Please read these instructions carefully before attempting to 

install, operate or service the Panasonic product. Please 

carefully read the “GENERAL SAFETY INFORMATION”. 

Failure to comply with instructions could result in personal 

injury or property damage. Please explain to users how to 

operate and maintain the product after installation and this 

manual should be presented to users. Please retain this 

manual for future references.

RG-C1315LA

 The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage 
 caused when the denotation is disregarded and improper use is performed. 

To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always 
observe the following safety precautions.

WARNING

CAUTION

Denotes a potential hazard that could result in serious injury or death.

Denotes a hazard that could result in minor injury.

Denotes a hazard that could result in property damage.

The following symbols are used to classify and describe the type of instructions to be observed.

This symbol is used to alert users not to disassemble the equipment.

This symbol is used to alert users to make sure of grounding when using the equipment with the grounding 
terminal.

This symbol is used to alert users to a specific operating procedure that must be followed in order to 
operate this unit safely.

This symbol is used to alert users to a specific operating procedure that must not be performed.

See page 12 for “Panasonic Warranty Sheet”.

GENERAL SAFETY INFORMATION

Ventilating Fan

INSTALLATION INSTRUCTIONS

C1 3 1 5 L4 2 0 A

Summary of Contents for RG-C1315LA

Page 1: ...s of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions WARNING CAUTION Denotes a potential hazard that could result in serious injury or death Denotes a hazard that could result in minor injury Denotes a hazard that could result in property damage The following symbols are used to classify and describe the type of instructions ...

Page 2: ...icient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel Ducted exhaust fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit These models are UL listed for tub and shower enclosur...

Page 3: ...e A damper for preventing air counter flow is provided The blower uses a high capacity sirocco fan developed to reduce the noise level The lighting unit is an energy saving LED lighting device that uses one 10 W LED lamp and produces almost the same illumination as a standard 40 W incandescent lamp Night light feature consumes around 0 1 to 0 4 W These products are listed by UL under UL file No E7...

Page 4: ... parts are present 4 Part name Appearance Quality Grille Flex Z Fast bracket with 4 tapping screws ST4 2X20 1 1 Part name Appearance Quality 1 4 Installation instructions Warranty sheet Self drilling screw This device complies with Part 15B of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interf...

Page 5: ...DC motor techology The DC motor is 30 70 more energy efficient than the minimum ENERGY STAR requirements Pick A Flow Feature This product comes with Pick A Flow speed options The Pick A Flow switch on the face of the product allows the option to choose 130 or 150 CFM This product can run continuously or intermittently depending upon the needs of the owner Pick A Flow switch RG C1315LA 130 CFM 130 ...

Page 6: ...opening and extend Align and install bracket to joist by using 2 preinstalled tapping screws Flex Z Fast bracket position can be adjusted from 16 to 24 406mm to 610mm between joists Install Flex Z Fast bracket Joist 2 Tapping screws ST4 2X20 Flex Z Fast bracket Align 2 Joist Flex Z Fast bracket Joist Align the edge of Flex Z Fast with the edge of the ceiling opening on the side where the adapter w...

Page 7: ...low all the local electrical safety codes as well as the National Electrical Code NEC Use UL approved wire nuts to connect fan wires After connecting wires replace junction box cover Insert and secure fan body Insert fan body and slide into adaptor assembly until the flange overlaps the Flex Z Fast bracket 1 INSTALLATION RETROFIT CONTINUED 4 3 AC120V 60Hz LIVE IN 3 Joist 4 2 Tapping screws ST4 2X2...

Page 8: ...ted and secure fill gap between flange and ceiling with caulk or other sealant to prevent air leakage Joist Joist 1 Install grille Insert the mounting springs into the slot as shown to mount grille to fan body 1 Drywall Mounting spring Gloves Grille Insert the grille mounting spring on the wiring side into the slot and insert the plug connector into the housing of the lighting unit 2 Before turnin...

Page 9: ...by removing the machine screw M4X8 before installation 1 Install Flex Z Fast bracket Flex Z Fast bracket position can be adjusted from 16 to 24 406mm to 610mm between joists Unit inches mm Joist Bend down 4 tabs 1 2 2 Tapping screws ST4 2X20 Flex Z Fast bracket Align 1 2 Align and install bracket to joist by using 2 preinstalled tapping screws Bend down 4 tabs and align bracket to the joist Follow...

Page 10: ...soak resin parts in water over 140 F 60 C Remove grille 1 Gloves Slot Grille Mounting spring 1 Remove grille by pulling down one mounting spring Disonnect the wire from the receptacle then pull down the other mountain spring 2 3 Remove dust and dirt from fan body using a vacuum cleaner Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Reinstall g...

Page 11: ... inches roof jack wall cap or soffit vent with backdraft damper Mechanically connect duct to termination and seal with mastic or approved foil faced tape 2 3 ft straight run before elbow In attic installation caulk box to drywall Short piece of flexible duct helps alignment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints Insulation Foil tape tightly covers all m...

Page 12: ...n how long an implied warranty lasts so the above exclusions or limitation may not apply to you Obtain Product Information and Operating Assistance locate your nearest distributor or make Customer Service and Literature requests by visiting our Web Site at us panasonic com ventfans or send your request by E mail to ventfans us panasonic com You may also contact us directly at 1 866 292 7299 Monday...

Page 13: ... incendio avería y daños materiales o en el equipo siempre cumpla con las siguientes medidas de seguridad ADVERTENCIA PRECAUCIÓN Indica peligro de lesión grave o muerte Indica peligro de lesión menor Indica peligro de daños materiales Los siguientes símbolos se utilizan para clasificar y describir el tipo de instrucciones que deben cumplirse Este símbolo se emplea para indicar a los usuarios que n...

Page 14: ...os NFPA por sus siglas en inglés y la Sociedad Estadounidense de Ingenieros de Calefacción Refrigeración y Aire Acondicionado ASHRAE por sus siglas en inglés y las autoridades normativas locales Los ventiladores con ductos siempre deben tener descarga hacia el exterior Si este equipo se instalará sobre una tina o una regadera debe estar identificado como adecuado para este tipo de uso y debe conec...

Page 15: ...por un transformador integral El motor está diseñado para tener una larga vida de funcionamiento respuesta dinámica alta márgenes de velocidad más altos con ahorro de energía La rejilla que cubre el cuerpo del ventilador es del tipo de resorte con extracción rápida Se suministra un amortiguador para prevenir la contracorriente de aire El soplador usa un ventilador siroco de alta capacidad desarrol...

Page 16: ...cuidadosamente el equipo del cartón Consulte la lista de accesorios suministrados para verificar que todas las partes están presentes 4 Nombre de la pieza Apariencia Cantidad Parrilla Soporte Flex Z Fast con 4 tornillos punta de broca ST4 2X20 1 1 Este dispositivo cumple la parte 15B de las Normas FCC Su funcionamiento está sujeto a las siguientes dos condiciones 1 Este dispositivo no puede causar...

Page 17: ...logía de motor de DC El motor de DC permite un uso de la energía de un 30 70 más eficiente que los requerimientos mínimos de ENERGY STAR Función Pick A Flow Este producto incluye opciones de velocidad Pick A Flow El selector Pick A Flow en el lado del producto permite seleccionar entre las opciones 80 y 110 CFM Este producto puede funcionar de forma continua o intermitente dependiendo de las neces...

Page 18: ...sconecte el conector de enchufe del receptáculo y quite el adaptador del cuerpo del ventilador retirando el tornillo para metales M4X8 antes de la instalación 1 Tornillo para metales M4X8 Cuerpo del ventilador Adaptador 1 La posición del soporte Flex Z Fast puede ajustarse entre las viguetas de 16 a 24 pulgadas 406mm a 610mm Instalar soporte Flex Z Fast Vigueta Soporte Flex Z Fast Alinear 2 Viguet...

Page 19: ...aluminio aprobada Se necesita un ducto circular de 6 pulgadas para conectar la parte correspondiente del adaptador 3 Inserte el cuerpo del ventilador hasta que la brida traslape el soporte Flex Z Fast 1 7 INSTALACIÓN RENOVACIONES CONTINUACIÓN 3 Vigueta 4 Extienda 3 4 Extienda el soporte a la otra vigueta Instale el soporte a la vigueta usando 2 tornillos punta de broca previamente instalados 2 Tor...

Page 20: ...ECAUCIÓN Parrilla Techo Guantes Resorte de montaje Sellar 1 2 Vigueta Vigueta 1 Despúes de terminar el trabajo del techo rellene el espacio entre la brida y el techo con masilla u otro sellador para evitar fugas de aire Ajuste el selector Pick A Flow Consulta las indicaciones en el capítulo FUNCIONES Página 5 Instalar parrilla Inserte el otro resorte de montaje en la ranura como se muestra y monte...

Page 21: ...ia abajo las 4 pestañas y alinee el soporte a las viguetas Siga los pasos de INSTALACIÓN RENOVACIONES 1 Siga los pasos 4 a 7 de INSTALACIÓN RENOVACIONES 3 4 Extender soporte a la otra vigueta Instale el soporte a la vigueta usando los 2 tornillos punta de broca previamente fijados La posición del soporte Flex Z Fast puede ajustarse entre las viguetas de 16 a 24 pulgadas 406mm a 610mm INSTALACIÓN C...

Page 22: ...a parrilla jalando hacia abajo uno de los resortes de montaje y luego el otro 2 3 Quite el polvo y la suciedad del cuerpo del extractor utilizando una aspiradora Con un paño humedecido con detergente de cocina quite toda suciedad del cuerpo del ventilador Seque con paño limpio Vuelva a instalar la parrilla Mantenimiento de la unidad 1 Limpie la parrilla No coloque en agua caliente Use detergente d...

Page 23: ...uido y el uso del equipo Use la ruta más corta y directa posible de instalación del ducto para obtener el mejor rendimiento y evite instalar el ventilador con ductos más pequeños que los recomendados El aislamiento alrededor de los ductos permite reducir la pérdida de energía e inhibir el crecimiento de moho Es posible que los ventiladores instalados con ductos existentes no alcance su flujo de ai...

Page 24: ...s y limitaciones anteriores podrían no aplicarse a su caso Para presentar una reclamación contra la garantía deberá presentar el recibo de compra con la fecha y también la información relativa al Ejemplo de localización Ejemplo de placa de identificación Si se produjera un problema relacionado con este producto durante o después del período de garantía póngase en contacto con el Distribuidor o con...