1. Before servicing, unplug the power cord to prevent an electric 

shock.

2. When replacing parts, use only manufacturer’s recommended 

components for safety.

3. Check the condition of the power cord. Replace if wear or damage 

is evident.

4. After servicing, be sure to restore the lead dress, insulation 

barriers, insulation papers, shields, etc.

5. Before returning the serviced equipment to the customer, be sure 

to make the following insulation resistance test to prevent the 
customer from being exposed to a shock hazard.

 

 Insulation Resistance Test

1. Unplug the power cord and short the two prongs of the plug with 

a jumper wire.

2. Turn on the power switch.

3. Measure the resistance value with ohmmeter between the jumper 

AC plug and each exposed metal cabinet part, such as screw 
heads, control shafts, handle brackets, etc. Equipment with 
antenna terminals should read between 3M   and 5.2M   to all 
exposed parts. 

(Fig. A)

 Equipment without antenna terminals 

should read approximately infinity to all exposed parts. 

(Fig. B)

 / *

Note: Some exposed parts may be isolated from the chassis by 
design. These will read infinity.