20
Fig. 5-5
8
Select the KNOB TEST Item by either UP or DOWN
Cursor.
8
Execute the KNOB TEST Item by pressing the Enter Key.
8
When executing, the Self Check will start for the Knobs.
First select the Q Adjusting Knob of the EQ Section
indicate to turn to right (reverse indication of the RIGHT).
8
Turn the Q Adjusting Knob to right, indicate to turn to the
left (reverse indication of LEFT).
8
Turn the Q Adjusting Knob to left, indicate to press this
Knob (reverse indication of KNOB).
If press the Enter Key instead of the Knob, this Knob will
be released reverse indication and next Knob becomes
reverse indication (Skip Function).
8
Press the Q Adjusting Knob, indicate to next Knob and
check the same manner as above.
8
The Jog Dial do not have press function.
8
The Self Check will be end after check of the Jog Dial.
5.15. LCD Test (LCD TEST)
8
Referring to Fig. 5-5, select the LCD TEST Item by either
UP or DOWN Cursor.
8
Execute the LCD TEST Item by pressing the Enter Key.
8
When executing, all face of the LCD is turn on (White
Indication) and off (Blue Indication) repeatedly by three
seconds.
8
Press the Enter Key to finish this Self Check Item.
5.16. Memory Initialize (MEMORY INITIALIZE)
8
Referring to Fig. 5-5, select the MEMORY INITIALIZE
Item by either UP or DOWN Cursor.
8
Execute the MEMORY INITIALIZE Item by pressing the
Enter Key.
8
When executing, all contents of the Memories such as the
Current, Scene, Library, Automation and. etc. have been
cleared and return to the initial contents which set in the
factory.
3.17. Execution of Upgrade Function (PROG-
RAM UPGRADE)
8
Referring to Fig. 5-5, select the PROGRAM UPGRADE
Item by either UP or DOWN Cursor.
8
Execute the PROGRAM UPGRADE Item by pressing the
Enter Key and all loaded programs in the ROM is deleted.
Note: All Programs loaded in the ROM IC have
been deleted if the Program Upgrade
Function is executed.
Must be need careful caution for execution
this function.
5.18. Fader Calibration Test (FADER CALIB-
RATION TEST)
8
Move the Cursor to most bottom position by either UP or
DOWN Cursor Key.
8
Select the Diagnostic Item (DIAG6) by either LEFT or
RIGHT Cursor Key.
8
Press the Enter Key, the Diagnostic Menu 6 as shown in
Fig. 5-6 is displayed.
Fig. 5-6
8
Select the FADER CALIBRATION Item by either UP or
DOWN Cursor.
8
Execute the FADER CALIBRATION Item by pressing the
Enter Key.
8
When executing, all Faders (21 pcs.) have been calibrated
and displayed measured value.
DIAG5
DIAGNOSTICS
LCD TEST
T.C.
SCENE
KNOB TEST
SEL CH
MEMOTY INITIALIZE
PROGRAM UPGRADE
DIAG4
DIAG5
DIAG6
EXIT
DIAG2
DIAG3
DIAG1
EQ
RIGHT
LEFT
SW
RIGHT
LEFT
SW
RIGHT
LEFT
SW
RIGHT
LEFT
SW
RIGHT
LEFT
RIGHT
LEFT
SW
RIGHT
LEFT
SW
RIGHT
LEFT
SW
PAN/ASSIGN
DYNAMICS
AUX
JOG
DIAG6
DIAGNOSTICS
T.C.
SCENE
FADER CALIBRATION TEST
SEL CH
DIAG4
DIAG3
DIAG5
DIAG6
EXIT
DIAG2
DIAG1
AVERAGE
STATUS
1
100
OK
2
100
OK
3
100
OK
4
100
OK
5
100
OK
6
100
OK
7
100
OK
8
100
OK
AVERAGE
STATUS
9
100
OK
10
100
OK
11
100
OK
12
100
OK
13
100
OK
14
100
OK
15
100
OK
16
100
OK
AVERAGE
STATUS
17
100
OK
18
100
OK
19
100
OK
20
100
OK
21
100
OK