SETTING
5
Ū
Part description
Adjustment
panel
Cover
OUT 2 area operation
indicator (Yellow)
Sensing area selection switch
(Left area) (Note 2)
Sensing area selection switch
(Right area) (Note 2)
External control function
selection switch (Note 1)
Adjacent right OUT 1 area
sensitivity adjuster
OUT 2 area
sensitivity adjuster
OUT 1 area operation
indicator (Red)
Adjacent left OUT 1 area
sensitivity adjuster
OUT 1 area
sensitivity adjuster
Output operation mode
selection switch
R L
INT. D ON
EXT. L ON OFF
R
L
OUT2
OUT1
OUT1
OUT2
Notes: 1)
2)
Incorporated in
PX-24ES
and
PX-23ES
.
Not incorporated in
PX-26
.
Ū
Sensitivity adjustment procedure
Notes: 1)
2)
3)
4)
5)
6)
When adjusting the sensitivity of OUT 1 area, adjacent right OUT 1 area and adjacent left
OUT 1 area, this is the OUT 1 area operation indicator (red).
When adjusting the sensitivity of OUT 2 area, this is the OUT 2 area operation indicator
(yellow).
Set areas other than the area you are adjusting as ineffective.
Use the accessory adjuster screwdriver to turn the distance adjuster slowly. Turning with
excessive force will cause damage the adjuster.
During the sensitivity adjustment, do not let your hand be detected.
Sensitivity adjustment for the auxiliary sensor is performed with the sensitivity adjuster on
the auxiliary sensor (
PX-SB1
). Refer to the instruction manual enclosed with auxiliary sen-
sor (
PX-SB1
).
After sensitivity adjustment, fit the adjustment panel cover using the accessory adjuster
screwdriver. The tightening torque should be 0.5N
m or less.
㧙
㧙
Place an object to be detected at the required sensing position, and
turn the sensitivity adjuster gradually clockwise and mark the point
where the indicator turns on (Note 1).
ԝ
㧙
Ԝ
After all the adjustments are made, the operator must confirm that the
sensing area is set correctly by observing the detection of the object as
it approaches from different directions.
Carry out steps
ԙ
,
Ԛ
and
ԛ
for each of the areas OUT 2, OUT 1, ad-
jacent left / right OUT 1 and auxiliary sensors (if they are connected).
ԛ
Ԛ
ԙ
Turn the sensitivity adjuster fully counterclockwise to the minimum
sensing range position.
Ԙ
Set the output operation mode switch to the L. ON mode position (Light-ON).
Step Sensitivity adjustment
Operation
Remove the object and turn the sensitivity adjuster further clockwise.
Find out the point where the indicator turns on again. Make sure that
the difference between point and is 1 div., or more, on the scale.
Then, set the sensitivity adjuster at point .
Ū
Setting procedure
Notes: 1)
2)
Not required when auxiliary sensor (
PX-SB1
) is not used.
Max. two auxiliary sensors can be connected.
ԝ
㧙
After completion of the above adjust-
ments, the adjustment panel cover must
be fitted back on the adjustment panel.
The tightening torque should be
0.5N
㨯
m or less.
Ԝ
Operation mode
selection
OUT 1 and OUT 2 operate in the
same mode.
(Select either of the two.)
Both Light-ON.
Both Dark-ON.
Select the operation mode for OUT 1
and OUT 2 with the operation mode
selection switch.
INT. D ON
R
L
EXT. L ON
OFF
Light-ON
INT. D ON
R
L
EXT. L ON
OFF
Dark-ON
Right OUT 1
auxiliary area
Left OUT 1
auxiliary area
(Note 1)
Adjust the sensitivity for the right OUT
1 auxiliary area and left OUT 1 auxili-
ary area with the sensitivity adjusters
of the auxiliary sensor (
PX-SB1
).
Refer to the instruction manual
enclosed with auxiliary sensor
(
PX-SB1
).
Adjacent right
OUT 1 area
Adjacent left
OUT 1 area
Adjust the sensitivity for the adjacent
right OUT 1 area and adjacent left
OUT 1 area with the their sensitivity
adjusters.
Sensitivity for OUT 2 area, OUT
1 area, adjacent right OUT 1 area
and adjacent left OUT 1 area can
be adjusted independently.
OUT 1 area
Adjust the OUT 1 area sensitivity with
the OUT 1 area sensitivity adjuster.
Refer to '
٨
OUT 2 area and
OUT 1 area
'.
OUT 1 area =
Left area
+
Center area
+
Right area
OUT 2 area
Adjust the OUT 2 area sensitivity with
the OUT 2 area sensitivity adjuster.
Refer to '
٨
OUT 2 area and
OUT 1 area
'.
OUT 2 area =
Left area
+
Center area
+
Right area
ԛ
Ԛ
Selection of
main sensor
sensing areas
Select the sensing area of the main
sensor with the sensing area selection
switch.
Refer to '
٨
Selection of sensing area
'.
For
PX-24ES
and
PX-23ES
, set the ex-
ternal control function selection switch
in the adjustment panel to 'INT.' side.
Sensing area of
PX-26
main
sensor is not selectable.
PX-24ES
and
PX-23ES
allow
sensing area selection with ex-
ternal signal, too.
Refer to '
EXPLANATION OF FUNC-
TIONS
' of
٨
Eternal control function
.
6
ԙ
Connection of
auxiliary sensor
(Note 1)
If you expect to use the optional auxili-
ary sensors (
PX-SB1
), connect them
to the main sensor and install them.
(Note 2)
Refer to the instruction manual
enclosed with auxiliary sensor
(
PX-SB1
).
Ԙ
Mounting and
preparation
Mount the main sensor at the required lo-
cation. Open the adjustment panel cover.
Refer to '
MOUNTING
'.
2
Step
Item
Description
Remarks
Sensitivity adjustment
Ū
Selection of sensing area
R
L
OFF
R
L
OFF
R
L
OFF
OFF
R
L
Sensing area selection
switch
Sensing area pattern of main sensor
Right and left sides are
ineffective.
Sensing width is mini-
mum.
Right and left sides are
effective.
Sensing width is maxi-
mum.
Right side is ineffective.
Left side is effective.
Sensing width is nar-
row on the right side.
Right side is effective.
Left side is ineffective.
Sensing width is nar-
row on the left side.
Note: Adjacent left and right OUT 1 areas are always effective.
To make them ineffective, turn their sensitivity adjusters fully counterclockwise.
Ū
OUT 2 area and OUT 1 area
Note: The sensitivity of the OUT 2 and the OUT 1 areas can be adjusted independently. Thus the
OUT 1 area can be set for a longer range than the OUT 2 area, in which case OUT 1 turns ON
before OUT 2.
<OUT 2 area>
Left area
Center area
Right area
<OUT 1 area>
Center area
Left area
Right area
Ū
Relationship between OUT 2, OUT 1 and effective area
<Area where OUT 2 is enabled.>
Left area
Center area
Right area
Adjacent
left OUT 1
area
Adjacent
right OUT 1
area
Main sensor
Left
auxiliary
sensor
Right
auxiliary
sensor
Left OUT 1
auxiliary area
Right OUT 1
auxiliary area
OUT 2 area
<Area where OUT 1 is enabled.>
Left area
Center area
Right area
Adjacent
left OUT 1
area
Adjacent
right OUT 1
area
Main sensor
Left
auxiliary
sensor
Right
auxiliary
sensor
Left OUT 1
auxiliary area
Right OUT 1
auxiliary area
OUT 1 area
Ū
Description of sensing areas
Center
area
Adjacent left
OUT 1 area
Adjacent right
OUT 1 area
Main sensor
Multi core cable
(power, I/O)
10-core cable
with connector
Left auxiliary
sensor
Right OUT 1 auxiliary
area
Left OUT 1 auxiliary
area
Sensing area
Left area
Right area
Right auxiliary
sensor