GENERAL GUIDELINES
1.
IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked
by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is
essential that these critical parts should be replaced
with manufacturerís specified parts to prevent shock,
fire or other hazards. Do not modify the original design
without permission of manufacturer.
2. An Isolation Transformer should always be used during
the servicing of VCR whose chassis is not isolated from
the AC power line. Use a transformer of adequate
power rating as this protects the technician from
accidents resulting in personal injury from electrical
shocks. It will also protect VCR from being damaged by
accidental shorting that may occur during servicing.
3. When servicing, observe the original lead dress. If a
short circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
4. After servicing, see to it that all the protective devices
such as insulation barriers, insulation papers shields are
properly installed.
5. After servicing, make the following leakage current
checks to prevent the customer from being exposed to
shock hazards.
LEAKAGE CURRENT COLD CHECK
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed
metallic cabinet part on the equipment such as
screwheads, connectors, control shafts, etc. When the
exposed metallic part has a return path to the chassis,
the reading should be between 1 M
W
and 5.2 M
W
.
When the exposed metal does not have a return path to
the chassis, the reading must be infinity.
LEAKAGE CURRENT HOT CHECK
(See figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5 k
W
, 10 W resistor, in parallel with a 0.15
µF capacitor, between each exposed metallic part on
the set and a good earth ground, as shown in figure 1.
3. Use an AC voltmeter, with 1 k
W
/V or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 V
RMS.
A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks.
Leakage current must not exceed 1/2 mA. In case a
measurement is outside of the limits specified, there is
a possibility of a shock hazard, and the equipment
should be repaired and rechecked before it is returned
to the customer.
Figure 1
1 SAFETY PRECAUTIONS
3
PV-V4525S / PV-V4535S-K / PV-455S-K
Summary of Contents for PV-455S-K
Page 13: ...Fig D2 13 PV V4525S PV V4535S K PV 455S K ...
Page 30: ...PV V4525S PV V4535S K PV 455S K 30 ...
Page 32: ...PV V4525S PV V4535S K PV 455S K 32 ...
Page 37: ...10 EXPLODED VIEWS 10 1 MECHANISM SECTION 37 PV V4525S PV V4535S K PV 455S K ...
Page 38: ...10 2 CHASSIS FRAME AND CASING PARTS SECTION 38 PV V4525S PV V4535S K PV 455S K ...
Page 39: ...10 3 PACKING PARTS AND ACCESSORIES SECTION 39 PV V4525S PV V4535S K PV 455S K ...