background image

Replacing the lamp unit

Lamp unit replacement period

The lamp unit for the projection TV should be replaced after approximately 5,000 hours of use in the normal usage
mode.

 Warning display after 5,000 hours of use

When the power has been turned off after over 5000 hours of
continued use, LAMP REPLACE will be displayed for approximately
1 min. The next time the power is turned on.
A warning message to urge the replacement of the lamp will be
displayed in red at the center of the screen.

LAMP

TEMP

R-STANDBY
G-POWER ON

POWER

Lamp unit

Speaker grille

TEMP

LAMP

POWER INDICATOR
R-STANDBY
G-POWER ON

POWER SWITCH

LAMP  REPLACE

Resetting the counter

After replacing lamp, please make sure to undergo below procedure in order to reset the lamp lifetime counter.

CH

VOL

VOL

CH

ACTION

VOLUME

Press down both VOLUME DOWN button on the unit and ACTION button
on the Remote Control at the same time for more than 1 second.

When successful, the 3 LED on the set’s front panel (Power / Lamp /
Temperature) will flash for 5 seconds.

LAMP

TEMP

R-STAND BY
G-POWER ON

POWER

 

Important Points to keep in mind

When replacing the lamp unit with a new one, pay attention to the following points.

Warning:

 

 Because the temperature of the lamp unit is elevated immediately after its use, a direct touch to it may cause

burns. Please allow the lamp to cool before handling or replacing the lamp unit.

Cautions for Lamp Unit Replacement:

 

 Handle the removed old lamp unit carefully. If abusing it, it may have a risk of explosion.

 

 Wear gloves when replacing the lamp unit.

 

 If replacing the lamp unit becomes necessary during the operation of the projection TV, follow the procedure below

to turn off the power and wait until the lamp unit cools completely.

1. Press the POWER button on the remote control unit.

2. Wait for about 90 seconds until the cooling fan stops.
* The lamp cooling fan will continue to operate for about 90 seconds after turning off the power. Do not

unplug the power cord from the outlet until the fan has stopped. Avoid interrupting the power line such as
by using circuit breakers or switchable power strips.

3. After the cooling fan has stopped, turn off the MAIN POWER switch on the front of the projection TV.

4. Unplug the power cord from the outlet.

Replacing the lamp unit

171

PT-
52DL10

Reviews: