-60-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
Range Note
11 CR - GAIN AREA V START
500
0 - 1000
12 Image AREA H WIDTH
YCBCR Level Acquiring Area
13
0 - 4095
13 Image AREA V HIGHT
YCBCR Level Acquiring Area Height
9
0 - 4095
14
Y - OFFSET TARTGET
4
1 - 255
15 CB OFFSET TARGET
128
1 - 255
16 CR OFFSET TARGET
128
1 - 255
17
Y-GAIN TARGET
217
1 - 255
18 CB-GAINTARGET
237
1 - 255
19 CR-GAINTARGET
237
1 - 255
20 OFFSET torelance
Torelance of OFFSET Adj.
1
1 - 255
21 GAIN torelance
Torelance of GAIN Adj.
1
1 - 255
Group
270
CUSTOM(Aspect1
0 Scaler Horizontal
Horizontal Scaler Edit
100
68-132
1 Sclaler Vertical
Vertical Scaler Edit
100
68-132
2 Connect
Seperate/Connect Edit
0
0-1
0:Seperate, 1: Connect
3 Position Horizontal
Horizontal Postion Correction
100
85-115
4 Position Vertical
Vertical Position Correct
100
85-115
5 Aspect Enable
0
0 - 1
0: False, 1: True
Group
275
DLV Illuminance Sensor
0 Illuminance
measurements(ADC)
Illuminance measurements(ADC)
-
0-255
* Read only
1 Illuminance data(Lx)
Illuminance data(Lx)
-
0-1023
* Read only
2
DLV_Level
DLV_Level value
-
0-3
* Read only
3 L1 Value(Floor)
Reference value switching Level1->
0 when (illuminance value)
36
0-255
4 L2 Value(Floor)
Reference value switching Level 0->
at the time of a value (brightness)
67
0-255
5 L3 Value(Floor)
Reference value switching Level2->
when a (illuminance value)
86
0-255
6 L4 Value(Floor)
Reference value switching Level1->
when 2 (illuminance value)
121
0-255
7 L5 Value(Floor)
Reference value switching Level3->
when 2 (illuminance value)
161
0-255
8 L6 Value(Floor)
Reference value switching Level2->
3 o'clock (illuminance value)
202
0-255
9 L1 Value(Ceiling)
Reference value switching Level1->
0 when (illuminance value)
18
0-255
10 L2 Value(Ceiling)
Reference value switching Level 0>
at the time of a value (brightness)
21
0-255
11 L3 Value(Ceiling)
Reference value switching Level2->
when a (illuminance value)
24
0-255
12 L4 Value(Ceiling)
Reference value switching Level1->
when 2 (illuminance value)
32
0-255
13 L5 Value((Ceiling)
Reference value switching Level3->
when 2 (illuminance value)
39
0-255
14 L6 Value(Ceiling)
Reference value switching Level2->
3 o'clock (illuminance value)
51
0-255
15
DLV ON_Level
Level of DLL in the ON mode of DLV
3
0-3
Group
276
DLV Image quality correction
0
Color correction gain (PW)
To enable / disable color correction
PW gain during DLV Auto / On
1
0-255
0:Enabel, 1:Disable
1
correction gain user R
(Gamma)
To enable / disable user R gain
compensation at the time of DLV
Auto / On
1
0-255
0:Enabel, 1:Disable
2
Correction Sub Gamma
(Gamma)
To enable / disable Sub Gamma
correction when the DLV Auto / On
1
0-255
0:Enabel, 1:Disable
3
Sharpness correction (PW)
Enable / disable the correction of
sharpness when DLV Auto / On
1
0-255
0:Enabel, 1:Disable
Group
280
AutoPC Adjust
0 AutoPCAdjustEnable
Auto-PC Adj Operation Enable if Un-
supported Signal Input
0
0-1
0:Enabel, 1:Disable
1 Frequency Step
Frequency Steps of Total Dot
1
0-3
2 Frequency Threshold
Total Dot Freqency Threshold
5
0-10
0[]<-- - --> 10[Not matched]
3 Fine Phase
Do Phase Adj after Total Dot Adj.
1
0-1
0;Excutes Fine Phase; 1:Not Excute
4
BLKDET
Black Level Detection Area
1
0 - 7
5
PHASEMSK
Phase Detection Filter
0
0 - 3
0: Effective All Bit,
1: Disable Lower 1 bit
2: Disable Lower 2 bit, 3: Disable
Lower 3 bit
Group
290
PanelType
Summary of Contents for PT-VX500U
Page 83: ...83 IC Block Diagrams CXA3828GL E S H IC561 TLV320AIC3105 Audio control IC5001...
Page 84: ...84 IC Block Diagrams PW190 Scaler IC301 TB6608FNG IRIS Driver IC601...
Page 85: ...85 IC Block Diagrams SSC9512S Power Switching IC604 PIC32MX695F512H Netwrok IC8801...
Page 86: ...86 IC Block Diagrams TPS54286 DC DC converter IC7811 STR A6079 Power switching IC603...
Page 116: ......