66
Using WebBrowser
(cont.)
※
Example of email message sent
If [NORMAL] is selected under [MAIL CONTENTS]
A
If you have completed the email settings
B
If an error occurs
If [SIMPLE] is selected under [MAIL CONTENTS]
C
If you have completed the email settings
D
If an error occurs
=== Panasonic projector report(CONFIGURE) ===
Projector Type
: F300NT
----- E-mail setup data -----
TEMPERATURE WARNING SETUP
MINIMUM TIME
at [ 60] minutes interval
INPUT AIR TEMPERATURE Over [ 32C / 89F ]
ERROR
[ ON ]
LAMP RUNTIME
[ ON ] at REMAIN [ 400] H
LAMP RUNTIME
[ ON ] at REMAIN [ 200] H
FILTER REMAIN
[ ON ] at REMAIN [ 500] H
FILTER REMAIN
[ ON ] at REMAIN [
0] H
INPUT AIR TEMPERATURE [ ON ]
PERIODIC REPORT
Sunday
[ ON ] Monday [ ON ] Tuesday [ ON ] Wednesday [ ON ]
Thursday [ ON ] Friday [ ON ] Saturday [ ON ]
00:00 [ ON ]
01:00 [ ON ]
02:00 [ ON ]
03:00 [ ON ]
04:00 [ ON ]
05:00 [ ON ]
06:00 [ ON ]
07:00 [ ON ]
08:00 [ ON ]
09:00 [ ON ]
10:00 [ ON ]
11:00 [ ON ]
12:00 [ ON ]
13:00 [ ON ]
14:00 [ ON ]
15:00 [ ON ]
16:00 [ ON ]
17:00 [ ON ]
18:00 [ ON ]
19:00 [ ON ]
20:00 [ ON ]
21:00 [ ON ]
22:00 [ ON ]
23:00 [ ON ]
----- check system -----
MAIN CPU BUS
[
OK
]
FAN
[
OK
]
INPUT AIR TEMPERATURE [
OK
]
OUTPUT AIR TEMPERATURE [
OK
]
LAMP REMAIN TIME
[
OK
]
LAMP STATUS
[
OK
]
INPUT AIR TEMP.SENSOR [
OK
]
OUTPUT AIR TEMP.SENSOR [
OK
]
BATTERY
[
OK
]
ACF UNIT
[
OK
]
FILTER REMAIN
[
OK
]
(Error code 00 00 00 00 00 00 00 00)
Input air temperature
:-44 degC / -47 degF
Output air temperature
: 30 degC / 86 degF
SET RUNTIME
188 H
POWER ON
0 times
LAMP ON
21 times
LAMP HIGH
30 H
LAMP REMAIN 4970 H
FILTER REMAIN
0 H
-------- Current status ---------
MAIN VERSION
1.00.0
NETWORK VERSION
1.00
LAMP STATUS
LAMP=OFF
INPUT SIGNAL
NETWORK
---
---kHz / ---Hz
REMOTE2 STATUS
DISABLE
----- Wired Network configuration -----
DHCP Client OFF
IP address 10.69.104.183
MAC address 00:40:63:00:00:12
----- Wireless Network configuration -----
IP address 169.254.213.197
MAC address 00:0E:10:02:6E:7E
Wed Sep 17 13:45:42 2008
----- Memo -----
=== Panasonic projector report(ERROR) ===
Projector Type : FW300NTU
----- check system -----
MAIN CPU BUS [ FAILED ]
FAN [ OK ]
INPUT AIR TEMPERATURE [ OK ]
OUTPUT AIR TEMPERATURE [ OK ]
LAMP REMAIN TIME [ OK ]
LAMP STATUS [ FAILED ]
INPUT AIR TEMP.SENSOR [ FAILED ]
OUTPUT AIR TEMP.SENSOR [ OK ]
BATTERY [ OK ]
ACF UNIT [ FAILED ]
FILTER REMAIN [ OK ]
(Error code 84 44 00 00 10 00 00 04)
Input air temperature :-44 degC / -47 degF
Output air temperature : 29 degC / 84 degF
SET RUNTIME 194 H
LAMP ON 21 times
LAMP HIGH 36 H
LAMP REMAIN 4964 H
------- Remaining filter --------
QUANTITY 0 %
APPOROX. TIME 0 H
-------- Current status ---------
MAIN VERSION 1.00.0
NETWORK VERSION 1.000
LAMP STATUS LAMP=OFF
INPUT SIGNAL NETWORK ---
---kHz / ---Hz
REMOTE2 STATUS DISABLE
----- Wired Network configuration -----
DHCP Client OFF
IP address 10.69.104.183
MAC address 00:40:63:00:00:12
----- Wireless Network configuration -----
IP address 169.254.213.197
MAC address 00:0E:10:02:6E:7E
Wed Sep 17 13:45:42 2008
----- Memo -----
[ F300NT ]
[ F300NT ]