NETWORK menu (continued)

Network setup

You can make detailed wired LAN settings.

Press ▲▼ to select [Network setup], and press <SELECT> button.

The detailed [Network setup] screen will be displayed.

Press ▲▼ to select an item, and change the setting according to the instructions.

DHCP 

(DHCP client function)

On:

If a DHCP server exists in the network to which the 

projector is connected, the IP address will automatically be 

acquired.

Off:

If a DHCP server does not exist in the network to which 

the projector is connected, additionally set [IP address

], 

[Subnet mask

 

] and [Default gateway

 

].

IP address 

(Display of IP address and setting)

Enter the IP address if DHCP server is not used.

Subnet mask

(Displaying and setting the subnet mask)

If not using a DHCP server, enter the subnet mask.

Default gateway 

 

(Display of gateway address and setting)

Enter the gateway address if DHCP server is not used.

DNS

Sets IP address of the DNS server.

 

“Glossary” (See page 

26)

Press ▲▼◄► to select [Set], and press <SELECT> button.

Save the current network settings.

Before using the DHCP server, make sure the DHCP server is already functioning.
For details of IP address, subnet mask, gateway and DNS, ask the network administrator.

  

Default wired LAN settings

The following settings are set before the projector leaves the factory.

DHCP

Off

IP address

192.168.10.100

Subnet mask

255.255.255.0

Default gateway

192.168.10.1

DNS 1
DNS 2

Summary of Contents for PT-EX16K

Page 1: ...ommercial Use SO K2TA This manual explains the network operation of the projector For information other than the network operation such as the usage inspection and replacement of parts see Operating Instructions Projector Operations ENGLISH Model No PT EX16K ...

Page 2: ...Check your computer 4 Necessary environment for computers to be connected 4 NETWORK menu 5 Displaying the NETWORK menu 5 Projector name 6 Network setup 7 Network control 8 Network status 9 Network factory default 10 Connecting with Wired LAN 10 Computer operation 10 Using Web Browser 11 Accessing from the Web browser 11 PJLink protocol 23 Control commands 23 PJLink security authorization 23 Contro...

Page 3: ...ir password Do not give out your password even if directly asked by a third party representing themselves as Panasonic Corporation Always use on a network that has safety protection such as a firewall implemented WEB control See page 11 The following operations are possible when using WebBrowser Setting and adjusting the projector Displaying the projector status Setting for message transmission PJ...

Page 4: ...wired LAN switched on Computer without a built in wired LAN function Is your wired LAN adapter properly recognized Is your wired LAN adapter switched on Install the wired LAN adapter driver beforehand For details on how to install the driver refer to the instructions accompanying the wired LAN adapter Check 3 For WebBrowser WebBrowser is necessary to use WEB control Compatible OS Windows XP Window...

Page 5: ...splaying the menu with the following procedure Displaying the NETWORK menu Press the MENU button on remote control 1 The main menu appears Select NETWORK with the buttons 2 The network menu appears Press the SELECT button 3 You can select the sub menu item Unavailable items on the menu screen are grayed out and cannot be selected ...

Page 6: ...me and press SELECT button 1 Select characters with the buttons 2 and press the SELECT button to enter the projector name Select SET with the buttons and press 3 the SELECT button Select CANCEL to undo the changes and then press the SELECT button Select YES or No with the buttons and 4 press the SELECT button PT EX16K Projector name ...

Page 7: ... of IP address and setting Enter the IP address if DHCP server is not used Subnet mask Displaying and setting the subnet mask If not using a DHCP server enter the subnet mask Default gateway Display of gateway address and setting Enter the gateway address if DHCP server is not used DNS Sets IP address of the DNS server Glossary See page 26 Press to select Set and press SELECT button 3 Save the cur...

Page 8: ...rojector from a computer connected to the network Press to select Network control 1 Press SELECT button or the button to access the submenu 2 Select WEB control PJLink control Command control AMX D D items with the buttons For more details about AMX D D visit http www amx com ...

Page 9: ...d Network status This function shows the LAN setting environment of the currently selected projector Press to select Network status 1 Press SELECT button or the button to show the information of the current 2 projector status ...

Page 10: ...settings are the default settings the computer can be used with the following network settings DHCP Off IP address 192 168 10 101 Subnet mask 255 255 255 0 Default gateway 192 168 10 1 DNS 1 DNS 2 Network factory default You can reset the network setting to the factory default of the projector Press to select Network factory default and press SELECT button 1 A confirmation box appears and select Y...

Page 11: ...lick OK to display the Projector status 4 page Projector status page is displayed Avoid activating two or more Web browser simultaneously to work out setting or control actions Change the password first of all Administrator privileges enable the use of all functions User privileges enable the use of only Projector status Network status Basic control Advanced control and Change password If the pass...

Page 12: ...tatus to display the Status information page This page displays the projector statuses established for the items shown below 1 Displays the type of projector 2 Displays the firmware version of the projector main unit 3 Displays the power source status 4 Displays the selection of the lamps 5 Displays the serial number of the projector 6 Displays the firmware version of the network 7 Displays the sh...

Page 13: ...wrong LAMP REMAIN TIME The lamp runtime has exceeded the prescribed cumulative time and it is now time to replace the lamp LAMP STATUS The lamp has failed to light Wait a short while for the lamp to cool off and then turn on the power INTAKE AIR TEMP SENSOR Trouble has occurred in the sensor used to detect the intake air temperature Consult your dealer EXHAUST AIR TEMP SENSOR Trouble has occurred ...

Page 14: ...ormation of the network Displays the configuration details of wired LAN Basic control page To move from another page click Projector control then Basic control 1 Power On Off control 2 Use these to select the input signals 3 Switches image mode 4 Turn on or off the Shutter function 1 2 3 4 ...

Page 15: ... control page 1 Execute Auto setup function 2 Operations on Image adjust 3 Operations on Screen mode 4 Operations on Rear Ceiling 1 2 3 4 9 Operations on Test pattern 10 Return to factory default setting 5 Operations on Keystone function 6 Operations on Lens shift 7 Operations on Zoom 8 Operations on Focus 5 6 7 8 9 10 ...

Page 16: ...t 2 New user name input field 3 New password input field 4 New password input field re enter for confirmation 5 Button for executing password change User mode A user can change password only 1 Current password input field 2 New password input field 3 New password input field re enter for confirmation 4 Button for executing password change When changing the administrator account both Current user n...

Page 17: ...ttings window appears showing the current settings To change the LAN settings click Change To return to the previous window click Back Complete the detailed settings and click Next 3 When Next is clicked the next page appears enabling you to complete the detailed settings as desired Settings performed here are the same as the settings performed with the Network menu of the projector Click Submit 4...

Page 18: ...ected to the e mail server POP server DNS server etc Click Detailed set up then Ping test to display the Ping test page Display which appears when the connection was successful Display which appears when the connection failed 1 Enter the IP address of the server to be tested 2 Button for conducting the test 2 1 ...

Page 19: ...so that the recipient may easily identify the originator of the e mail maximum 63 characters 5 The user can modify the minimum time interval of temperature warning mail The default value is 60 minutes In this case the user cannot send another mail for 60 minutes after sending previous temperature warning mail even the set warning temperature is reached again 6 Select the temperature of the intake ...

Page 20: ...P server is set on this page when POP SMTP authentication is required for mail transmissions Click Detailed set up then Authentication set up to display the Authentication server setup page 1 Select the authentication method specified by your Internet service provider 2 Set this if SMTP authentication has been selected 3 POP server name field Available input characters Alphanumeric characters A Z ...

Page 21: ...21 Using Web Browser continued Contents of mail sent Mail with the contents shown below is sent when the e mail settings have been established ...

Page 22: ...ts shown below is sent when an error has occurred Command port set up page Set the port number to be used with command control Click Detailed set up Command port set up 1 Input the port number to be used with command control 2 Setting update button 1 2 ...

Page 23: ...ates other errors range 0 2 Definitions for each value from 0 to 2 are as follows 0 No error known 1 Warning 2 Error LAMP Lamp status query Parameters 1st digits 1 5 digits Lamp cumulative operating time 2nd digit 0 Lamp off 1 Lamp on INST Input selection list query The following are returned as parameters 11 12 31 32 33 21 22 13 25 46 47 48 49 NAME Projector name query The name set for NAME CHANG...

Page 24: ...enerate a 32 byte hash value from the following data using MD5 algorithm 3 xxxxxx yyyyy zzzzzzzz xxxxxx Administrator rights user name for WEB CONTROL Default user name is admin1 yyyyy Password of above administrator rights user Default password is panasonic zzzzzzzz 8 byte random number obtained in Step 2 Command transmission method Transmit using the following command format Transmitted data Hea...

Page 25: ...se data Data section Blank Mode Termination symbol NTCONTROL ASCII string 0x20 0 0x30 CR 0x0d 9 bytes 1 byte 1 byte 1 byte Mode 0 Non protect mode Command transmission method Transmit by the following command format Transmitted data Header Data section Termination symbol 0 0x30 0 0x30 Control command ASCII string CR 0x0d 1 byte 1 byte Undefined length 1 byte Receive data Header Data section Termin...

Page 26: ...rea Network This is a network with a relatively narrow range such as inside a company 7 Subnet This limits the range of the IP addresses assigned to computers in order to divide the network into a number of sections during TCP IP connection The value used to divide the network at this time is called the subnetmask 7 10 Trademarks Microsoft and its logos Windows Windows XP Windows Vista Windows 7 a...

Page 27: ...ヱ ㄏ ㄔㄐㄏㄊ チヤㄐㄓㄑㄐㄓ ㄕㄊㄐㄏ Web Site http panasonic net avc projector Panasonic Corporation 2011 ...

Reviews: