Status asking commands

Command : Parameter

Function

Description

Callback

Q P W

Q S H

Q I N

Q O S

Q S T

Q $ L : p 1

Q $ L : p 2

Q $ L : p 3

Q $ L : p 4

Q S L

Q I B

Q G D

Q G T

Main power status

Shutter function status

Input signal status

On-screen display status

Projector run time

Lamp 1 run time

Lamp 2 run time

Lamp 3 run time

Lamp 4 run time

Lamp operation mode status

Optional board slot status

P in P status

Date setting status

Time setting status

On

Off

On

Off

RGB 1

RGB 2

Video

S-Video

DVI

AUX

On

Off

00000h – 99999h

0000h – 9999h

0000h – 9999h

0000h – 9999h

0000h – 9999h

Quad (four lamps)

Lamp 1 + 4

Lamp 2 + 3

Dual (two lamps)

Lamp 1 + 2 + 3

Lamp 1 + 2 + 4

Lamp 1 + 3 + 4

Lamp 2 + 3 + 4

Triple (three lamps)

Lamp 1

Lamp 2

Lamp 3

Lamp 4

Single lamp

ET-MD95SD1

ET-MD95SD3

ET-MD75DV

Uninstalled

Unknown

Not supported

Off

User 1

User 2

User 3

yyyymmdd (day of week) 

(*1)

 

hhmmss 

(*2)

 

0 0 1

0 0 0

1

0

R G 1

R G 2

V I D

S V D

D V I

A U X

1

0

0 0 0 0 0 - 9 9 9 9 9

0 0 0 0 - 9 9 9 9

0 0 0 0 - 9 9 9 9

0 0 0 0 - 9 9 9 9

0 0 0 0 - 9 9 9 9

0

1

2

3

4

5

6

7

8

9

1 0

1 1

1 2

1 3

M D 9 5 S D 1

M D 9 5 S D 3

M D 7 5 D V

N O N E

U N K N O W N

N O T   S U P P O R T

0

1

2

3

y 1 y 2 y 3 y 4 m 1 m 2 d 1 d 2 w

h 1 h 2 m 1 m 2 s 1 s 2

*

1

*

2

Day of wee

k

: Monday = 1, Tue

s

day = 2, ... 

S

unday = 7

S

et the date and time to UTC (univer

s

al time coordinated).

Command example

To set the on-screen display off, send the command as shown below.

ADZZ

OOS

:

0

;

ETX

ID Address

ZZ: ID ALL

Command

STX

Start

Character code 02

Parameter

End

Character code 03

NOTE: When sending commands without parameters, a colon (:) is not necessary.

Summary of Contents for PT-DW10000

Page 1: ... 1 S P E C F I L E Product Number PT DW10000 Product Name 3 Chip DLP Projector As of July 2007 Appearance and specifications are subject to change without notice ...

Page 2: ...33 75 kHz fV 60 Hz 1080 60i fH 33 75 kHz fV 60 Hz 1080 50i fH 28 13 kHz fV 50 Hz 1080 25p fH 28 13 kHz fV 25 Hz 1080 24p fH 27 00 kHz fV 24 Hz 1080 24sF fH 27 kHz fV 48 Hz 1080 30p fH 33 75 kHz fV 30 Hz 1080 60p fH 67 5 kHz fV 60 Hz 1080 50p fH 56 25 kHz fV 50 Hz Horizontal 15 75 15 63 kHz Vertical 50 60 Hz NTSC NTSC4 43 PAL PAL60 PAL N PAL M SECAM 50 40 with the ET D75LE6 from center of screen po...

Page 3: ...6p 1080 60i 1080 50i 1080 24p 1080 24sF 1080 25p 1080 30p 1080 60p 1080 50p 720 60p 720 50p EDID2 Compatible with non interlaced signals only VGA 640 x 480 U XGA 1 600 x 1 200 dot clock 25 162 MHz NOTE LAN terminals on the optional board can not be used Use the LAN terminal on the projector 3 m 9 8 Moulded plastic 578 x 320 x 643 mm 22 3 4 x 12 19 32 x 25 5 16 without lens 32 kg 70 5 lbs or less w...

Page 4: ...AC 13 A 15 A Dimensions Terminals 448 17 5 8 4 23 32 120 477 18 25 32 265 10 7 16 320 12 19 32 36 1 13 32 607 23 29 32 643 25 5 16 578 22 3 4 unit mm inch NOTE This illustration is not drawn to scale 1 Remote 1 input output 2 Remote 2 input 3 Serial input RS 232C 4 Serial input RS 422 5 Serial output RS 422 6 LAN connector 10Base T 100Base TX 7 Video input 8 Video output 9 S Video input 10 RGB 1 Y...

Page 5: ... 80 7 13 8 15 9 17 9 19 9 24 0 30 0 40 2 50 3 60 4 80 7 100 9 121 2 13 9 15 9 17 9 19 9 24 0 30 0 40 2 50 3 60 4 80 7 100 9 121 2 23 3 26 7 30 0 33 4 40 2 50 3 67 2 84 2 101 1 134 9 168 7 202 5 23 3 26 7 30 1 33 4 40 2 50 4 67 3 84 2 101 1 134 9 168 7 202 6 37 3 42 7 48 1 53 5 64 2 80 3 107 2 134 1 161 0 214 8 268 6 322 4 36 4 41 8 47 1 52 5 63 3 79 4 106 3 133 2 160 1 213 9 267 7 321 5 69 4 79 4 ...

Page 6: ... x 41 15 80 maximum L mm diagonal screen size in inches x 61 73 106 16 9 minimum L mm diagonal screen size in inches x 61 73 96 maximum L mm diagonal screen size in inches x 103 09 122 16 9 minimum L mm diagonal screen size in inches x 103 09 116 maximum L mm diagonal screen size in inches x 163 93 101 16 9 minimum L mm diagonal screen size in inches x 163 95 386 maximum L mm diagonal screen size ...

Page 7: ... 5 76 7 68 7 60 0 52 4 64 0 72 3 78 2 80 0 91 1 65 2 78 8 82 2 75 0 59 9 50 0 59 9 50 0 59 9 50 0 60 0 50 0 60 0 50 0 24 0 24 0 50 0 60 0 60 0 50 0 70 1 85 1 59 9 66 7 72 8 75 0 85 0 56 3 60 3 72 2 75 0 85 1 74 6 50 0 60 0 70 1 75 0 81 6 85 0 87 0 100 0 120 0 59 9 50 0 59 8 71 2 74 9 85 0 75 1 60 0 50 0 60 0 66 3 72 0 75 0 85 0 60 0 72 0 75 0 60 0 13 5 13 5 27 0 27 0 74 3 74 3 74 3 74 3 74 3 74 3 ...

Page 8: ...internally Ground Signal name RXD TXD GND No 1 2 3 4 5 Description NC Connected internally Connected internally NC Signal name RTS CTS No 6 7 8 9 CAUTIION It may not be possible to send or receive commands for about 10 to 60 seconds when the lamp is first turned on If this occurs wait for 60 seconds then try sending or receiving again When sending multiple commands be sure to wait for at least 0 5...

Page 9: ... Triple three lamps Lamp 1 Lamp 2 Lamp 3 Lamp 4 Single lamp Shutter on Shutter off P in P off User 1 User 2 User 3 Natural Standard Dynamic Cinema Graphic Low Middle High User 1 User 2 Default Date setting Time setting On screen display on On screen display off POWER STANDBY INPUT SELECT LAMP SELECT SHUTTER P IN P SELECT AUTO SETUP PICTURE MODE COLOR TEMPERATURE DATE TIME ON SCREEN PON POF IIS RG1...

Page 10: ...1 4 Lamp 2 3 Dual two lamps Lamp 1 2 3 Lamp 1 2 4 Lamp 1 3 4 Lamp 2 3 4 Triple three lamps Lamp 1 Lamp 2 Lamp 3 Lamp 4 Single lamp ET MD95SD1 ET MD95SD3 ET MD75DV Uninstalled Unknown Not supported Off User 1 User 2 User 3 yyyymmdd day of week 1 hhmmss 2 001 000 1 0 RG1 RG2 VID SVD DVI AUX 1 0 00000 99999 0000 9999 0000 9999 0000 9999 0000 9999 0 1 2 3 4 5 6 7 8 9 10 11 12 13 MD95SD1 MD95SD3 MD75DV...

Page 11: ...ed into the intake openings 500 mm 19 11 16 or more 500 mm 19 11 16 or more 500 mm 19 11 16 or more Operating the Projector Continuously 1 If the projector is to be operated continuously 24 hours use the lamp relay mode The projector cannot be operated continuously 24 hours in quad lamp mode Allow a minimum of two hours per day of non operation time if the projector is to be operated continuously ...

Reviews: