background image

26/51 

 

2.69. SXGA MODE 

Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 53h 58h 3Ah 

Character    A D Z Z  ;  O S X  : 

Hexadecimal *1  03h 

Character *2   

  Parameters (*1, *2) 

 SXGA 

SXGA+ 

Hexadecimal 30h 

31h 

Character 0 

 Response (Callback) 

In the period when the command can be accepted 

Hexadecimal  02h 4Fh 53h 58h 3Ah  *1  03h 

Character   O S X : *2  

Acceptability 

SECURITY STNDBY NO 

SIGNAL SHUTTER FREEZE TEST 

PATTERN REMOTE2 

No No  No  Yes No 

Yes 

Yes 

 

2.70. CONTRAST MODE 

Hexadecimal  02h 41h 44h 5Ah 5Ah 3Bh 56h 43h 52h 3Ah 

Character 

  A D Z Z  ;  V C R  : 

Hexadecimal  *1 *3 *5 03h 

Character 

*2 *4 *6   

  Parameters (*1, *2, *3, *4, *5, *6) 

 NORMAL 

HIGH 

Hexadecimal 30h  31h 

Character 0  1 

 Response (Callback) 

In the period when the command can be accepted 

Hexadecimal  02h 56h 43h 52h 3Ah  *1  *3  *5  03h 

Character  

*2 

*4 

*6 

 

Acceptability 

SECURITY STNDBY NO 

SIGNAL SHUTTER FREEZE TEST 

PATTERN REMOTE2 

No No Yes Yes 

No 

Yes 

Yes 

 

2.71. EDID 

Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 44h 42h 4Ch 3Ah 

Character   A D Z Z ; O E D : 

Hexadecimal *1  03h 

Character *2   

  Parameters (*1, *2) 

 EDID1 

EDID2 

(PC) 

Hexadecimal 31h 

32h 

Character 1 

 Response (Callback) 

In the period when the command can be accepted 

Hexadecimal 02h 44h 42h 4Ch 3Ah *1 03h 

Character    O E D  :  *2   

Acceptability 

SECURITY STNDBY NO 

SIGNAL SHUTTER FREEZE TEST 

PATTERN REMOTE2 

No No Yes Yes 

No 

Yes 

Yes 

 

2.72.  DVI Signal Level 

Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 58h 58h 3Ah 44h 56h 

Character    A D Z Z  ;  V X X  :  D V 

Hexadecimal 

49h 

49h 

30h 

3Dh 

2Bh *1 *3 *5 *7 *9 03h 

Character  I  I  0 = + *2 *4 *6 *8 

*10  

  Parameters (*1, *2, *3, *4, *5, *6, *7, *8, *9, *10) 

 0—255:PC 

16—235 

Hexadecimal  30h 30h 30h 30h 30h 30h 30h 30h 30h 31h 

Character  0 0 0 0 0 0 0 0 0 1 

 Response (Callback) 

In the period when the command can be accepted 

Hexadecimal 02h 56h 58h 58h 3Ah 44h 56h 49h 49h 30h 

Character   V X X : D V I  I 0 

Hexadecimal 

3Dh 

2Bh *1 *3 *5 *7 *9 03h 

Character =  +  *2 *4 *6 *8 *10   

Acceptability 

SECURITY STNDBY NO 

SIGNAL SHUTTER FREEZE TEST 

PATTERN REMOTE2 

No No Yes Yes 

No 

Yes 

Yes 

Summary of Contents for PT-D4000

Page 1: ...Panasonic Projector RS 232C Control Specifications PT DW5100 D5700 D4000...

Page 2: ...rt STX ID Separator semicolon Command Separator colon 1 byte 4 bytes 1 byte 3 bytes 1 byte Subcommand Operation Sign Parameters End ETX 5 bytes 1 byte 1 byte 5 bytes 1 byte Operation Specifies the met...

Page 3: ...L ID8 AD08 ID31 AD31 ID54 AD54 Group M AD0M ID9 AD09 ID32 AD32 ID55 AD55 Group N AD0N ID10 AD10 ID33 AD33 ID56 AD56 Group O AD0O ID11 AD11 ID34 AD34 ID57 AD57 Group P AD0P ID12 AD12 ID35 AD35 ID58 AD5...

Page 4: ...mand after that period has elapsed When sending several commands be sure to wait for a response from the projector and send the next command after 0 5 seconds or more pass It might take time by the ti...

Page 5: ...BY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Yes Note When you confirm whether to have succeeded in power off confirm it by QPW Query Power command after receiving the call...

Page 6: ...cter D V I Response Callback In the period when the command can be accepted Hexadecimal 02h 49h 49h 53h 3Ah 1 3 5 03h Character I I S 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST...

Page 7: ...key Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Fh 43h 55h 03h Character A D Z Z O C U Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 43h 55h 03h Character O C U 2 12 Do...

Page 8: ...1 2 3 4 5 6 7 8 9 Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 4Eh 4Bh 3Ah 1 03h Character O N K 2 2 20 LAMP SELECT Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 4Ch 50h...

Page 9: ...0 0 0 1 0 2 0 3 0 4 5 6 7 8 Hexadecimal 30h 35h 30h 36h 30h 37h 30h 38h Character 0 5 0 6 0 7 0 8 Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 43h 53h 3Ah 1 3...

Page 10: ...44h 59h 4Eh 47h 52h 41h Character D Y N G R A STANDARD CINEMA NATURAL Hexadecimal 53h 54h 44h 43h 49h 4Eh 4Eh 41h 54h Character S T D C I N N A T Response Callback In the period when the command can b...

Page 11: ...ters 1 2 3 4 DEFAULT USER MIDDLE HIGH Hexadecimal 31h 30h 30h 34h 30h 31h 30h 32h Character 1 0 0 4 0 1 0 2 Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh 54h 45h...

Page 12: ...h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1 0 0 2 61 62 63 Hexadecimal 30h 36h 31h 30h 36h 32h 30h 36h 33h Character 0 6 1 0 6 2 0 6 3 Response Callback In the period when the command can...

Page 13: ...30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1 0 0 2 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h Character 2 5 3 2 5 4 2 5 5 Response Callback In the period when the comman...

Page 14: ...0h 38h 30h 39h 31h 30h Character 0 8 0 9 1 0 Response Callback In the period when the command can be accepted Hexadecimal 02h 56h 57h 48h 3Ah 1 3 03h Character V W H 2 4 Acceptability SECURITY STNDBY...

Page 15: ...2h 41h 44h 5Ah 5Ah 3Bh 56h 4Eh 53h 3Ah Character A D Z Z V N S Hexadecimal 1 03h Character 2 Parameters 1 2 OFF 1 2 3 Hexadecimal 30h 31h 32h 33h Character 0 1 2 3 Response Callback In the period when...

Page 16: ...accepted Hexadecimal 02h 56h 54h 48h 3Ah 1 3 5 03h Character V T H 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 No No No Yes No Yes Yes Note It is possible to spec...

Page 17: ...Character 0 5 0 0 5 1 0 5 2 997 998 999 Hexadecimal 39h 39h 37h 39h 39h 38h 39h 39h 39h Character 9 9 7 9 9 8 9 9 9 Response Callback In the period when the command can be accepted Hexadecimal 02h 4Fh...

Page 18: ...S Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 54h 44h 3Ah Character A D Z Z V T D Hexadecimal 1 3 5 7 03h Character 2 4 6 8 Parameters 1 2 3 4 5 6 7 8 330 331 Hexadecimal 30h 33h 33h 30h 30h 33h 33h 31h C...

Page 19: ...ER402 when the value of more than number in which 30 is subtracted from number of total dots is specified 2 52 TOTAL LINES Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 54h 4Ch 3Ah Character A D Z Z V T L H...

Page 20: ...4Ch 54h 3Ah Character A D Z Z V L T Hexadecimal 1 3 5 03h Character 2 4 6 Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1 0 0 2 253 254 255 Hexadecim...

Page 21: ...6 English German French Hexadecimal 45h 4Eh 47h 44h 45h 55h 46h 52h 41h Character E N G D E U F R A Spanish Italian Japanese Hexadecimal 45h 53h 50h 49h 54h 4Ch 4Ah 50h 4Eh Character E S P I T L J P...

Page 22: ...6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 No No No Yes No Yes Yes 2 60 BLANKING LOWER Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 44h 42h 42h 3Ah Character A D Z Z D B B H...

Page 23: ...4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 No No No Yes No Yes Yes 2 62 BLANKING LEFT Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 44h 42h 4Ch 3Ah Character A D Z Z D B L H...

Page 24: ...h 39h 35h 33h Character 2 9 5 2 2 9 5 3 2046 2047 Hexadecimal 37h 30h 34h 36h 37h 30h 34h 37h Character 7 0 4 6 7 0 4 7 Response Callback In the period when the command can be accepted Hexadecimal 02h...

Page 25: ...L SHUTTER FREEZE TEST PATTERN REMOTE2 No No Yes Yes No Yes Yes 2 67 Color Correction Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 56h 43h 4Dh 3Ah Character A D Z Z V C M Hexadecimal 1 03h Character 2 Parameter...

Page 26: ...s No Yes Yes 2 71 EDID Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 44h 42h 4Ch 3Ah Character A D Z Z O E D Hexadecimal 1 03h Character 2 Parameters 1 2 EDID1 EDID2 PC Hexadecimal 31h 32h Character 1 2 Respons...

Page 27: ...Time Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 54h 53h 54h 3Ah Character A D Z Z T S T Hexadecimal h1 h2 m1 m2 s1 s2 03h Character Parameters h1 h2 Hour 2 digits m1 m2 Minute 2 digits s1 s2 Second 2 digits...

Page 28: ...RGB2 Hexadecimal 02h 52h 47h 32h 03h Character R G 2 VIDEO Hexadecimal 02h 56h 49h 44h 03h Character V I D S VIDEO Hexadecimal 02h 53h 56h 44h 03h Character S V D DVI Hexadecimal 02h 44h 56h 49h 03h C...

Page 29: ...D C I N N A T 2 82 Query COLOR Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 56h 43h 03h Character A D Z Z Q V C Response Callback In the period when the command can be accepted Hexadecimal 02h 1 3 5 03h C...

Page 30: ...2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes No Yes Yes Yes Yes Yes Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0...

Page 31: ...0 0 1 0 0 2 253 254 255 Hexadecimal 32h 35h 33h 32h 35h 34h 32h 35h 35h Character 2 5 3 2 5 4 2 5 5 2 89 Query W BAL HIGH G Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 48h 47h 03h Character A D Z Z Q H G...

Page 32: ...iod when the command can be accepted Hexadecimal 02h 1 3 5 03h Character 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes No No Yes Yes Yes Yes Parameters 1 2 3 4...

Page 33: ...2h 1 3 5 03h Character 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes No No Yes Yes Yes Yes Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h...

Page 34: ...be accepted Hexadecimal 02h 1 3 5 7 03h Character 2 4 6 8 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes No No Yes Yes Yes Yes Parameters 1 2 3 4 5 6 7 8 0 1 2 Hexadec...

Page 35: ...Hexadecimal 32h 39h 35h 32h 32h 39h 35h 33h Character 2 9 5 2 2 9 5 3 2046 2047 Hexadecimal 37h 30h 34h 36h 37h 30h 34h 37h Character 7 0 4 6 7 0 4 7 2 103 Query ASPECT Hexadecimal 02h 41h 44h 5Ah 5Ah...

Page 36: ...y SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes No No Yes Yes Yes Yes VIDEO S VIDEO RGB1 RGB2 YPBPR1 YPBPR2 DVI No No Yes Yes Yes Yes No Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30...

Page 37: ...GB1 RGB2 YPBPR1 YPBPR2 DVI No No Yes Yes No No No Parameters 1 2 3 4 5 6 7 8 306 307 Hexadecimal 30h 33h 30h 36h 30h 33h 30h 37h Character 0 3 0 6 0 3 0 7 2046 2047 Hexadecimal 32h 30h 34h 36h 32h 30h...

Page 38: ...Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes No No Yes Yes Yes Yes Parameters 1 2 3 4 5 6 0 1 2 Hexadecimal 30h 30h 30h 30h 30h 31h 30h 30h 32h Character 0 0 0 0 0 1...

Page 39: ...the command can be accepted Hexadecimal 02h 45h 44h 42h 49h 30h 3Dh 2Bh Character E D B I 0 Hexadecimal 1 3 5 7 9 03h Character 2 4 6 8 10 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST P...

Page 40: ...ter 2 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes No No Yes Yes Yes Yes 2 119 Query SVGA MODE Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 53h 58h 03h Character A D Z Z...

Page 41: ...period when the command can be accepted Hexadecimal 02h 1 3 5 03h Character 2 4 6 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Yes Parameters 1...

Page 42: ...44h 5Ah 5Ah 3Bh 51h 53h 50h 03h Character A D Z Z Q S P Response Callback FRONT DESK Hexadecimal 02h 30h 03h Character 0 REAR DESK Hexadecimal 02h 34h 03h Character 1 FRONT CEILING Hexadecimal 02h 31...

Page 43: ...L Hexadecimal 32h 03h Character 2 Response Callback In the period when the command can be accepted Hexadecimal 02h 1 3 5 7 03h Character 2 4 6 8 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE...

Page 44: ...50h 03h Character A D Z Z Q L P Response Callback When the lamp is Normal type and HIGH setting Hexadecimal 02h 30h 03h Character 0 When the lamp is Normal type and LOW setting Hexadecimal 02h 31h 03h...

Page 45: ...TTER FREEZE TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Yes 2 134 Query FAN CONTROL1 Hexadecimal 02h 41h 44h 5Ah 5Ah 3Bh 51h 46h 4Dh 03h Character A D Z Z Q F M Response Callback NORMAL Hexadecimal 0...

Page 46: ...03h Character Parameters y1 y4 Year 4 digits m1 m2 Month 2 digits d1 d2 Day 2 digits w Day of the week Mon 1 Tue 2 Wed 3 Thu 4 Fri 5 Sat 6 Sun 7 Set it by UTC Coordinated Universal Time Example Friday...

Page 47: ...cter 2 Lamp 1 ON Lamp 2 ON Hexadecimal 02h 33h 03h Character 3 Acceptability SECURITY STNDBY NO SIGNAL SHUTTER FREEZE TEST PATTERN REMOTE2 Yes Yes Yes Yes Yes Yes Yes 2 141 Query System Settings Hexad...

Page 48: ...the period when the command can be accepted Hexadecimal 02h 44h 56h 49h 49h 30h 3Dh 2Bh Character D V I I 0 Hexadecimal 1 3 5 7 9 03h Character 2 4 6 8 10 Acceptability SECURITY STNDBY NO SIGNAL SHUTT...

Page 49: ...7 25 ID60 3C Group S 92 ID15 0F ID38 26 ID61 3D Group T 93 ID16 10 ID39 27 ID62 3E Group U 94 ID17 11 ID40 28 ID63 3F Group V 95 ID18 12 ID41 29 ID64 40 Group W 96 ID19 13 ID42 2A Group A 80 Group X 9...

Page 50: ...ay accumulate dust Power ON bit26 For extension The value is undefined bit25 Lamp 2 ON time error Shutdown Lamp 2 reset bit24 Lamp 1 ON time error Shutdown The lamp ON time exceeds specified cumulativ...

Page 51: ...st Becomes lower than the warning release temperatur e during power on Power ON bit11 For test The value is undefined MAIN POWER ON bit10 For extension The value is undefined bit09 For extension The v...

Reviews: