-47-
Troubleshooting
Error
Error code
Error infomation
Normal
0
-
Power Failure
1000
MAIN,
P_FAIL
Errors on the power supply lines or Fan control
1001
WHEEL, ERROR
Error on the color wheel
Temperature Error
2000
Sensor A detects abnormal temperature. (IC8801-ROOM)
2001
Sensor A fails measurement. (IC8801)
2100
Sensor B detects abnormal temperature. (IC8821-LAMP)
2101
Sensor B fails measurement. (IC8821)
2102
Sensors B-A temperature error.
2200
Sensor C detects abnormal temperature. (IC8811-DMD)
2201
Sensor C fails measurement. (IC8811)
2202
Sensors C-A temperature error.
Lamp Error
3000
Lamp1 fails on
3001
Lamp1 goes out
3002
Communication Error on Lamp1
Error log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and
select the group "220" and no. "0" to "49". The error code is
displayed on the data column. The description of the error
code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service adjustment menu opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
220
0
1
2
3
:
:
49
[
<- Latest Error
[
[
[
:
:
[
How to reset the error log
1. Enter the service mode, and select the group "220" and no. "50".
2 The history log will be reset when the data value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service adjustment menu operation".