3.4 Configuration of IP address (Basic)

(1)  Connect this device to your PC with the separately sold optional RJ45-DSub 

9-pin console cable, then start up the terminal emulator (ZEQUO assist Plus, 
etc.).

(2)  Pressing Enter key once opens Login screen. Enter UserName and Password 

(the default is "manager" for both). 

(Screen 1)

(3)  The command input screen is displayed. 

(Screen 2)

(4)  Enter the IP address and subnet mask using the following command. 

(Screen 3)

>enable
#configure
(config)#interface vlan 1
(config-if)#ip address 192.168.1.254 255.255.255.0

(5)  Enter the following command to save the setting.

(config-if)#exit
(config)#exit
#copy running-config startup-config

(6)  Since the following screen is displayed, enter “Y” and the settings will be saved. 

(Screen 4)

 

Confirm that the settings have been normally saved.

(7)  After configuring, start with the terminals, etc. which are connected to the 

network, and conduct PING testing on the IP addresses that have been input, 
and confirm whether or not that the settings are proper being reflected.

Summary of Contents for PN290496-NZ

Page 1: ...y customers are not covered by the warranty I1120 40822 Printed in Japan MGA ML4TWPoE Model No PN290496 TH PN290496 MY PN290496 ID PN290496 SG PN290496 NZ The instruction manuals CLI Version Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ew pewnw english datadownload index html 2 12 7 Higashi Shimbashi Minato ku Toky...

Page 2: ...ifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 2 2 PoE power supply function 3 Installation and Configuration 3 1 Using 10GBASE T 3 2 Grounding Cable Connection 3 3 Mounting to rack 3 4 Configuration of IP address Basic Troubleshooting 3 7 8 8 9 11 11 12 15 17 18 18 19 20 21 23 ...

Page 3: ...could lead to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle with other cord pinch put under a heavy object and or heat it Damaged power cord could lead to fire short and or electric shock Do not unplug nor plug in the power plug with wet hands Deviation could lead to electrical shock and or equipment failure Do not insert or ...

Page 4: ...ocks and malfunctions Unplug the power cord if the STATUS ECO LED Status ECO mode blinks in orange system fault Deviation such as keep connecting for a long time could lead to fire Handle the Ethernet Switch carefully so that fingers or hands may not be damaged by twisted pair port SFP extension slot console port or power cord hook block If the device is going to be mounted onto a rack use the 2 i...

Page 5: ...s to environmental restrictions whereby the Ethernet Switch can be used Please isolate the business power lines and communication lines Isolate distribution lines and other distribution lines and low current power lines optical fiber cables metallic water conduits and gas conduits etc Noise may be generated in the communication lines which might cause communication glitches Do not connect any othe...

Page 6: ... to this Ethernet Switch through the power supply or ground wire connected to the power port leading to malfunction If a lightning surge current voltage may flow in through the power supply or ground wire it is recommended that you install a surge protective device SPD on the power port side of this Ethernet Switch 6 CAUTION When connecting IEEE802 3bt compatible devices to this device AWG24 and 6...

Page 7: ...ailure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covered by the warranty If it is used beyond the operating environmental temperatures then the protective devices will start working and the Ethernet Switch power will be shut off Do not block the ventilator of the Ethernet Switch Blocked ventilator induces the heat a...

Page 8: ...allows remote configuration changes and verifications of the Ethernet Switch Remotely configure the PoE settings for each port Ports 1 to 4 The connection status for each port is detected by the power saving mode and it can reduce the power consumption to required levels when not linked up Factory default deactivated Rapid Spanning Tree Protocol is supported allowing to build a system with redunda...

Page 9: ...d method Forwarding rate 100BASE TX Max 148 800 pps port 1000BASE T Max 1 488 000 pps port 2 5GBASE T Max 3 720 000 pps port 5GBASE T Max 7 440 000 pps port 10GBASE T Max 14 880 000 pps port MAC Address table Max 16K entry unit Buffer 2 0Mbyte unit EAP frame BPDU frame transmission Link Aggregation IEEE802 3ad Configurable up to 3 groups Max 6 ports per group VLAN IEEE802 1Q tagging VLAN protocol ...

Page 10: ...cheduler function PoE auto reboot function Port grouping function Multi cast address group registration function Power supply AC 100 240 V 50 60 Hz 3 8 A Power consumption Normally Max 303 W 32 5 W when not supplying power Min 20 8 W Silent fan control The fan rpm can be set in accordance with the usage environments If the fan rpm are set the maximum power supply will be automatically restricted I...

Page 11: ...urned ON Then POWER LED Power lights in green STATUS ECO LED Status ECO mode lights in orange and self diagnosis of hardware is executed On completion of self diagnosis POWER LED Power STATUS ECO LED Status ECO mode and TEMP LED Temperature sensor light in green and the Ethernet Switch starts operation as a Ethernet Switch As this Ethernet Switch succeeds in communicating with a terminal connected...

Page 12: ...ay out the twisted pair cables CAT5e or higher so that the cable lengths fit within 100 m 100BASE TX 1000BASE T 2 5GBASE T 5GBASE T 10GBASE T ports SFP expansion slots ports 5 6 SFP expansion modules can be mounted They are exclusively used with the twisted pair ports They automatically switch when the SFP expansion slots are linked Lay out the twisted pair cables CAT6 or higher so that the cable ...

Page 13: ...of the Ethernet Switch is exceeding 120 W TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 73 C factory default FAN Fan sensor LED Green Light The system is normally operating Orange Blink Fan failure STATUS ECO LED Status ECO mode Gree...

Page 14: ...h occurs and the ports are displayed which cannot be supplied power No device connected or the ECO mode is set Orange Blink It is sending and receiving just the control packet Link is established Transmitting and receiving data Link is established at 10 Gbps Link is established at 5 Gbps 2 5 Gbps 1000 Mbps or 100 Mbps or no device is connected 5G Green Light Off Link is established at 5 Gbps Link ...

Page 15: ...mode 2 5G mode 1G mode or loop history mode and the LED display switch button is not used for one minute or longer the mode automatically returns to a Base mode Status mode or ECO mode The Base mode is maintained even after the power is turned OFF Indication on the front panel and LED lamps You can display the following items using the LED display switch button Display for the connection with a co...

Page 16: ...nd received Shut down mode When loops are being detected the ports will be automatically linked down and none of the packets will be transmitted and received Just the loop detection packets from 30 seconds before the set restoration times will automatically be transmitted and received During loop is occurring or if loop has occurred within the latest 3 days LOOP HISTORY LED blinks to notify this I...

Page 17: ...etting then it operates with the set value When the requested power supply for the Ethernet Switch is exceeded and it gets overloaded the power supply to the low priority ports is stopped and the port LEDs right of the ports whose power supply have been stopped blink orange The priority settings for the power supply can be set and changed from the console etc Power supply while the PoE LIM LED is ...

Page 18: ... in regard to alien crosstalk noise and exogenous noise it is recommended that STP cables be used Communication might be affected due to exogenous noise to the cables The person responsible for laying the cables might request to select appropriate cables and to make improvements regarding environmental noise 1 Supported cable types 2 Cable laying environment Cat 5e or below Cat 6 Cat 6A Cannot be ...

Page 19: ... be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed during normal operation servicing or maintenance 5 Installation steps Step 1 Ensure the detachable power supply cord...

Page 20: ...witch supplied with the mount brackets to fix the mount brackets to the four holes on each side of the Ethernet Switch Then securely install the Ethernet Switch onto the rack using the four screws for a 19 inch rack mount supplied with the mount brackets or the screws supplied with the rack Right side Left side Screw holes for fixing the 19 inch rack mount brackets ...

Page 21: ...sing the following command Screen 3 enable configure config interface vlan 1 config if ip address 192 168 1 254 255 255 255 0 5 Enter the following command to save the setting config if exit config exit copy running config startup config 6 Since the following screen is displayed enter Y and the settings will be saved Screen 4 Confirm that the settings have been normally saved 7 After configuring s...

Page 22: ...ager Password MGA ML4TWPoE UserName manager Password MGA ML4TWPoE enable MGA ML4TWPoE configure MGA ML4TWPoE config interface vlan 1 MGA ML4TWPoE config if ip address 192 168 1 254 255 255 255 0 MGA ML4TWPoE config if UserName manager Password MGA ML4TWPoE enable MGA ML4TWPoE configure MGA ML4TWPoE config interface vlan 1 MGA ML4TWPoE config if ip address 192 168 1 254 255 255 255 0 MGA ML4TWPoE c...

Page 23: ...SE T 2 5GBASE T 5GBASE T or 10GBASE T standard Auto negotiation may have failed Check the port settings of this Ethernet Switch or the terminal settings Is the correct Port LED display mode selected using the LED display switch button The Port LED left lights in orange Loop is occurring By removing the loop orange LED will be turned off LOOP HISTORY LED Blinks in orange This is to notify that ther...

Page 24: ...t cable RJ45 8 8 used Is the cable connected to the port 1 4 that supports PoE power supply Ensure that either the port alone or the entire equipment is not overloaded Is the PoE power receiving device which is connected to the corresponding port compliant with any one of the IEEE802 3bt standard IEEE802 3at standard or IEEE802 3af standard Is the upper threshold of the power supply manually Manua...