Basic Instructions for the Use of This Product

  For inspection and/or repair, consult the retailer.

  Use commercial power supply from a wall socket, which is close and easily accessible to this 

Ethernet Switch.

  Unplug the power cord when installing or moving this Ethernet Switch.

  Unplug the power cord when cleaning this Ethernet Switch.

  Use this Ethernet Switch within the specifications. Deviation could lead to malfunction.

  Do not touch the twisted pair cable modular metal terminals which are connected to RJ45 

connectors (twisted pair ports) or the connectors, nor place them near electrically-charged 
objects. Static electricity could lead to equipment failure.

  Do not put the modular plug of the connected twisted pair cable on objects that can carry 

static charge, such as carpet. Do not place it in the proximity. Static electricity could lead to 
equipment failure.

  Do not put a strong shock, including dropping, to this Ethernet Switch. Deviation could lead 

to equipment failure.

  Before connecting a console cable to the console port, discharge static electricity, for example 

by touching metal appliance (do not discharge by touching this Ethernet Switch).

  Please use this Ethernet Switch in place where ambient temperature is from 0 to 50°C and, do 

not store and/or use this Ethernet Switch in the environment with the characteristics listed 
below.

  (Store and/or use this Ethernet Switch in the environment in accordance with the 

specification.)

-  High humidity. Possible spilled liquid (water).
-  Dusty. Possible static charge (such as carpet).
-  Under direct sunlight.
-  Possible condensation. High/low temperature exceeding the specifications environment.
-  Strong vibration and/or strong shock.

  Failure to satisfy the conditions above may result in a fire, electric shock, equipment failure, 

and/or malfunction. Such events are not covered by the warranty.

*If it is used beyond the operating environmental temperatures, then the protective devices 

will start working and the Ethernet Switch power will be shut off.

  Do not block the ventilator of the Ethernet Switch.

  Blocked ventilator induces the heat accumulation inside, causing equipment failure and/or 

malfunction.

  If used at a temperature out of the operating temperature range, deviation could lead to 

malfunction.

 

Operation is not guaranteed if a module other than the optional SFP extension modules 
(PN54022/PN54024) is inserted into the SFP extension slot.

  For the latest information about compatible SFP extension modules, check our website.

  When using two Ethernet Switches, do not stack them. When you place them side by side, 

allow for a space of 20 mm or more between them. This space is not necessary if you use 
supplied  connection brackets.

  When Ethernet Switches mounting to rack, leave a minimum of 20 mm space between them.

1. Please note that Panasonic shall not bear any liability whatsoever for any damages 

(this shall include, but is not limited to, lost earnings, lost opportunities, etc.) 

which were generated in relation to damages caused by operations and usage, 
or the inability to use this Ethernet Switch, whereby the customer does not follow 
this Installation Guide.

2. The contents described in this document may be changed without prior notice.
3. For any question, please contact the retailer where you purchased the product.

7

Summary of Contents for PN260493N-NZ

Page 1: ...ers are not covered by the warranty I0620 40822 Printed in Japan GA ML4TPoE Model No PN260493N TH PN260493N MY PN260493N ID PN260493N SG PN260493N NZ The instruction manuals Menu Version CLI Version Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ew pewnw english datadownload index html 2 12 7 Higashi Shimbashi Minato...

Page 2: ...res 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 2 2 PoE power supply function 3 Installation and Configuration 3 1 Grounding Cable Connection 3 2 Mounting to rack 3 3 Configuration of IP address Basic Troubleshooting 3 7 8 8 9 11 11 12 15 17 18 18 19 20 22 ...

Page 3: ...could lead to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle with other cord pinch put under a heavy object and or heat it Damaged power cord could lead to fire short and or electric shock Do not unplug nor plug in the power plug with wet hands Deviation could lead to electrical shock and or equipment failure Do not insert or ...

Page 4: ...links in orange system fault Deviation such as keep connecting for a long time could lead to fire Handle the Ethernet Switch carefully so that fingers or hands may not be damaged by twisted pair port SFP extension slot console port or power cord hook block If the device is going to be mounted onto a rack use the 2 installation brackets for 19 inch rack mounting which include the 19 inch rack mount...

Page 5: ...he age related degradation etc of components It is recommended that this Ethernet Switch be replaced about five years after it was installed Be careful in regards to environmental restrictions whereby the Ethernet Switch can be used Please isolate the business power lines and communication lines Isolate distribution lines and other distribution lines and low current power lines optical fiber cable...

Page 6: ...air cable leading to malfunction If you connect such a device it is strongly recommended that you install a surge protective device SPD on the twisted pair port side of this Ethernet Switch A lightning surge current voltage may be conducted to this Ethernet Switch through the power supply or ground wire connected to the power port leading to malfunction If a lightning surge current voltage may flo...

Page 7: ...der direct sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Failure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covered by the warranty If it is used beyond the operating environmental temperatures then the protective devices will start w...

Page 8: ...emotely configure the PoE settings for each port Ports 1 to 4 The connection status for each port is detected by the power saving mode and it can reduce the power consumption to required levels when not linked up Factory default deactivated Rapid Spanning Tree Protocol is supported allowing to build a system with redundancy The IEEE802 1p compatible QoS function is supported Supports triple authen...

Page 9: ...le up to 3 groups Max 6 ports per group VLAN IEEE802 1Q tagging VLAN protocol compatible Max 256 groups including the default VLAN Port based VLAN Internet Mansion function QoS IEEE802 1p compatible Supports 8 priority queues Management method ZEQUO assist Plus SNMP v1 v2c v3 Telnet SSH v2 Console WEB control screen Power supply function Ports 1 to 4 support the IEEE802 3at af compatible power sup...

Page 10: ...xternal dimensions 44 mm Height 210 mm Width 260 mm Depth Excluding protruding sections Operating environment Temperature 0 50 C Humidity 20 80 RH no condensation If it is used beyond the operating environmental temperatures then the protective devices will start working and the Ethernet Switch power will be shut off ...

Page 11: ...ll the LEDs are turned ON Then POWER LED Power lights in green STATUS ECO LED Status ECO mode lights in orange and self diagnosis of hardware is executed On completion of self diagnosis POWER LED Power STATUS ECO LED Status ECO mode and TEMP LED Temperature sensor light in green and the Ethernet Switch starts operation as a Ethernet Switch As this Ethernet Switch succeeds in communicating with a t...

Page 12: ...idge and Ethernet Switch can be connected to this port Install the device so that the length of twisted pair cable CAT5e or above becomes 100m or less SFP extension slot ports 5 6 Install SFP module It becomes exclusive usage with twisted pair port When SFP extension slot is linked the ports is automatically switched to SFP extension mode SFP port supports only the full duplex communication Consol...

Page 13: ...nsor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 74 C factory default STATUS ECO LED Status ECO mode Green Light Operating in status mode Green Blink Operating in ECO mode All Port LEDs left are turned off Orange Light Starting up Orange Blink Malfunction Con...

Page 14: ...ed at full duplex Off Link is established at half duplex or no device is connected Green Light Orange Blink Off LOOP HISTORY Green Light Loop has been detected within the last 3 days Off No loop detection history It is shut off via the loop detection and shutoff function storm control or the BPDU guard PoE are being supplied power Power is not being supplied or the PoE receiving equipment are not ...

Page 15: ...If the mode is changed to the GIGA mode DUPLEX mode or loop history mode and the LED display switch button is not used for one minute or longer the mode automatically returns to a Base mode Status mode or ECO mode The Base mode is maintained even after the power is turned OFF Indication on the front panel and LED lamps You can display the following items using the LED display switch button Display...

Page 16: ...mode The Base mode is maintained even after the power is turned OFF LED lamps for each mode and LED lamps for ports 1 to 6 correspond as shown in Table 1 see page 14 Turns on the port LED with a orange light when a loop occurs in the corresponding port The Loop shutoff mode has the following 2 types of modes Block mode factory default When loops are detected the port statuses are automatically blo...

Page 17: ...pply have been stopped blink in orange The priority settings for the power supply can be set and changed from the console etc Power supply while the PoE LIM LED is blinking in orange overload caused by the total power supplied by the Ethernet Switch When the power supply which is requested exceeds 30 W via a single port and the port LED right blinks in orange and the power supply is stopped Unplug...

Page 18: ...nding cable must be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed during normal operation servicing or maintenance 5 Installation steps Step 1 Ensure the detachable p...

Page 19: ...ht screws for fixing the rack mount brackets to the Ethernet Switch supplied with the mount brackets to fix the mount brackets to the four holes on one side of the Ethernet Switches Then use the two connection brackets and eight screws for fixing the connection brackets supplied with the mount brackets to securely fix the connection brackets to the connection screw holes on the front and back pane...

Page 20: ...using the following command Screen 3 enable configure config interface vlan 1 config if ip address 192 168 1 254 255 255 255 0 5 Enter the following command to save the setting config if exit config exit copy running config startup config 6 Since the following screen is displayed enter Y and the settings will be saved Screen 4 Confirm that the settings have been normally saved Screen 5 7 After con...

Page 21: ...d GA ML4TPoE enable GA ML4TPoE configure GA ML4TPoE config interface vlan 1 GA ML4TPoE config if ip address 192 168 1 254 255 255 255 0 GA ML4TPoE config if exit GA ML4TPoE config exit GA ML4TPoE copy running config startup config Destination filename startup config y n GA ML4TPoE Product Number PN260493N Firmware Version x x x xx MAC Address 00 50 40 xx xx xx Serial Number xxxxxxxxxxx UserName ma...

Page 22: ...T 100BASE TX or 1000BASE T standard Auto negotiation may have failed Check the port settings of this Ethernet Switch or the terminal settings Is the correct Port LED display mode selected using the LED display switch button The Port LED left lights in orange Loop is occurring By removing the loop orange LED will be turned off LOOP HISTORY LED Blinks in orange This is to notify that there is a port...

Page 23: ...a CAT5e or better straight cable RJ45 8 8 used Is the cable connected to the port 1 4 that supports PoE power supply Ensure that either the port alone or the entire equipment is not overloaded Is the Powered Device connected to the port compliant with the IEEE802 3at standard or IEEE802 3af standard Is the upper threshold of the power supply manually Manual set in the range of 15600 30000 mW When ...

Reviews: