Panasonic Photo IC PNA4601M Specifications Download Page 5

Request for your special attention and precautions in using the technical information and

semiconductors described in this book

(1)

If any of the products or technical information described in this book is to be exported or provided to non-residents, the laws and 

regulations of the exporting country, especially, those with regard to security export control, must be observed. 

(2) The technical information described in this book is intended only to show the main characteristics and application circuit examples 

of the products. No license is granted in and to any intellectual property right or other right owned by Panasonic Corporation or any 

other company. Therefore, no responsibility is assumed by our company as to the infringement upon any such right owned by any 

other company which may arise as a result of the use of technical information described in this book.

(3) The products described in this book are intended to be used for standard applications or general electronic equipment (such as office 

equipment, communications equipment, measuring instruments and household appliances). 

Consult our sales staff in advance for information on the following applications:

 Special applications (such as for airplanes, aerospace, automobiles, traffic control equipment, combustion equipment, life support 

systems and safety devices) in which exceptional quality and reliability are required, or if the failure or malfunction of the prod-

ucts may directly jeopardize life or harm the human body.

 Any applications other than the standard applications intended.

(4) The products and product specifications described in this book are subject to change without notice for modification and/or im-

provement. At the final stage of your design, purchasing, or use of the products, therefore, ask for the most up-to-date Product 

Standards in advance to make sure that the latest specifications satisfy your requirements. 

(5) When  designing  your  equipment,  comply  with  the  range  of  absolute  maximum  rating  and  the  guaranteed  operating  conditions 

(operating power supply voltage and operating environment etc.). Especially, please be careful not to exceed the range of absolute 

maximum rating on the transient state, such as power-on, power-off and mode-switching. Otherwise, we will not be liable for any 

defect which may arise later in your equipment.

     Even when the products are used within the guaranteed values, take into the consideration of incidence of break down and failure 

mode, possible to occur to semiconductor products. Measures on the systems such as redundant design, arresting the spread of fire 

or preventing glitch are recommended in order to prevent physical injury, fire, social damages, for example, by using the products.

(6) Comply with the instructions for use in order to prevent breakdown and characteristics change due to external factors (ESD, EOS, 

thermal stress and mechanical stress) at the time of handling, mounting or at customer's process. When using products for which 

damp-proof packing is required, satisfy the conditions, such as shelf life and the elapsed time since first opening the packages.

(7) This book may be not reprinted or reproduced whether wholly or partially, without the prior written permission of our company.

20080805

Summary of Contents for Photo IC PNA4601M

Page 1: ...s Ta 25 C 3 C Parameter Symbol Conditions Min Typ Max Unit Operating supply voltage VCC 4 7 5 0 5 3 V Supply current ICC No signal condition 1 8 2 4 3 0 mA Maximum reception distance 1 Lmax 8 0 10 0 m Low level output voltage 2 VOL L 8 0 m IOL 400 μA 0 35 0 5 V High level output voltage VOH No signal condition IOH 10 μA 4 75 4 80 V Low level pulse width 1 TWL1 L 8 0 m 16 pulse 200 400 600 µs TWL2 ...

Page 2: ... adjusted so that the output standard receiver unit VO may be 55 mV when transmitting waves duty 50 are output from the transmitter unit where the sensitivity to infrared emitters SIR of PNZ323B is 0 53 μA when the irradiance H is 12 45 μW cm2 2 The maximum detection distance of this specification is guaranteed by TWH and TWL being within the limits when constant 16 pulses are transmitted with the ...

Page 3: ... 100 20 VCC 5 V Transmitter Standard LED Transmission unit used 0 10 20 30 40 50 60 70 80 90 Note The peak is fO 20 100 80 60 40 Relative sensitivity S Carrier frequency kHz Relative sensitivity S 100 80 60 40 20 35 39 43 41 37 0 33 100 80 60 20 40 Wavelength λ nm Relative sensitivity S 700 900 1200 800 1000 1100 0 600 Lmax Ta S Carrier frequency S λ Directive characteristics ...

Page 4: ...SHE00064AEK This product complies with the RoHS Directive EU 2002 95 EC PNA4601M 4 Package Unit mm LPTLSN3S0001 Pin name 1 VO 2 GND 3 VCC ...

Page 5: ...han the standard applications intended 4 The products and product specifications described in this book are subject to change without notice for modification and or im provement At the final stage of your design purchasing or use of the products therefore ask for the most up to date Product Standards in advance to make sure that the latest specifications satisfy your requirements 5 When designing ...

Reviews: