PAN4620 802.15.4 and Bluetooth LE Module
5 Getting Started
Integration Guide Rev. 1.0
Page 21
5.2 Device Drivers
5.2.1 General
It might be necessary to install drivers for some components.
Please note that the “FTDI USB UART” and the “Segger J-Link” SWD debugger will provide
COM ports to the system.
On the PAN4620 USB evaluation board both COM ports can be used to open
a UART connection to the PAN4620 module.
5.2.2 FTDI USB UART
Having the drivers installed correctly is mandatory for all the examples
mentioned in this Guide.
Depending on the operating system that
is used, drivers for the “FTDI USB UART” might not be
installed automatically. If in doubt, please check the FTDI website and install the drivers
manually.
For further information please visit
https://www.ftdichip.com/Drivers/VCP.htm
5.2.3 Segger J-Link SWD Debugger
Depending on the operating system that
is used, drivers for “Segger J-Link” SWD debugger
might not be installed automatically. Having the drivers installed correctly is not strictly
mandatory for the basic example mentioned in this Quick Start Guide, but necessary for using
other software examples from NXP SDK.
If in doubt, please check the “Segger” website and install the drivers manually.
For further information please visit
https://www.segger.com/downloads/jlink/