PROCEDURE
F.I.P. DISPLAY
1. Turn on the Service Mode
1.Press the FF key and the
EJECT key simultaneously
for more than 3 seconds.
2. Activate the Service Mode 2
While keep pressing FF key,
press the EJECT key in
twice.
3. Activate the Entering Mode.
Press the EJECT key for
more than 3 seconds.
4. Set the Mode 2.
Press the CH UP key once.
5. Insert the alignment
cassette tape (VFJ8125H3F)
The PG Shifter Adjustment
starts automatically.
PROCEDURE
F.I.P. DISPLAY
6. When the sequence of the
automatic adjustment has
been terminated, the
following action has been
made.
* SUCCEED: The cassette
tape is ejected.
* ERROR: The "F20", "F21",
"F22" or "F23"is displayed.
Refer to next PG Shifter
Adjustment Self-Diagnosis
Indication Table regarding
the details of the indications.
7. Exit from Service Mode.
Press FF and EJECT keys
simultaneously in 6 times.
Then the FIP becomes
normal indication.
PG SHIFTER AUTOMATIC ADJUSTMENT SELF-DIAGNOSIS INDICATION