3.3.3 ADJUSTMENTS
3.3.4 PG SHIFTER ADJUSTMENT/(AUTOMATIC)
Fig.E1
Fig.E2
CONDITION: BURST SIGNAL OFF / 75 ohm TERMINATED
PROCEDURES
FIP DISPLAY
Press the FF and EJECT Keys
simultaneously for 3 seconds.
Press the FF and EJECT Keys
simultaneously twice.
Press the EJECT key for 3 seconds.
Press the CH UP key once.
Insert the Alignment cassette tape. (PAL:VFJ8125H3F)
When the sequence of the automatical adjustment has been terminated, the following action has been made.
*SUCCEED: The cassette tape is ejected.
*ERROR : The "F2"is displayed on the FIP.
(Check the Servo/Syscon circuit and Cylinder unit.)
Release the Service mode by pressing the EJECT and FF keys simultaneously in 6 times until the FIP becomes normal indication.