16
6.9
Steam Sensor NN-V689WB
1. Remove 1 screw holding steam sensor unit.
2. Disconnect CN2 connector from digital programmer circuit
board.
3. Remove exhaust guide from steam sensor unit.
4. Remove catch hooks on sensor mounting plate and air
guide.
5. Remove steam sensor from sensor mounting plate.
NOTE: When installing the steam sensor, make sure that
the direction of the steam sensor is as shown in
figure.
SENSOR MOUNTING PLATE
EXHAUST GUIDE
AIR GUIDE
HOOK
HOOK
SENSOR MOUNTING PLATE
METAL
SURFACE OF LEAD WIRE
(WHITE SURFACE)
SURFACE