3.2. Measurement of microwave output
The output power of the magnetron can be determined by performing IEC standard test
procedures. However,due to the complexity of IEC test procedures, it is recommended to test the
magnetron using the simple method outlined below.
Necessary Equipment:
*1 liter beaker *Glass thermometer / *Wrist watch or stopwatch
NOTE:
Check the line voltage under load.Low voltage will lower the
magnetron output. Take the temperature readings and heating time
as accurately as possible.
1. Fill the beaker with exactly one liter of tap water.Stir the water
using the thermometer and record the water temperature.
(recorded as T1).
2. Place the beaker on the center of glass tray. / Set the oven for High
power and heat it for exactly one minute.
3. Stir the water again and read the temperature of the water.
(recorded as T2).
4. The normal temperature rise at High power level for each model is
as shown in table.
TABLE (1L-1min.test)
9
Summary of Contents for NN-T793SF
Page 3: ...3 ...
Page 4: ...4 ...
Page 5: ...5 ...
Page 6: ...1 SCHEMATIC DIAGRAM APH 2 SCHEMATIC DIAGRAM CPH 6 ...
Page 7: ...3 MEASUREMENTS AND ADJUSTMENTS 7 ...
Page 16: ...16 ...
Page 21: ...21 ...
Page 22: ...13 DIGITAL PROGRAMMER CIRCUIT NN T783 APH NN T763 APH SCHEMATIC DIAGRAM 22 ...
Page 23: ...23 ...
Page 24: ...14 DIGITAL PROGRAMMER CIRCUIT NN S763 APH CPH NN S753 CPH SCHEMATIC DIAGRAM 24 ...
Page 25: ...25 ...
Page 26: ...15 DIGITAL PROGRAMMER CIRCUIT NN S753 APH NN S743 APH SCHEMATIC DIAGRAM 26 ...
Page 27: ...27 ...
Page 28: ...16 DIGITAL PROGRAMMER CIRCUIT PARTS LIST 28 ...
Page 39: ...SCHEMATIC DIAGRAM APH 7 SCHEMATIC DIAGRAM APH ...
Page 40: ... 8 SCHEMATIC DIAGRAM CPH SCHEMATIC DIAGRAM CPH ...
Page 65: ... 33 ...
Page 66: ... 34 ...