5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 1.4 ohm
Approx.: 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
COMPONENT TEST PROCEDURE
PRIMARY
TERMINAL
SECONDARY
WINDING
FILAMENT
WINDING
TERMINAL
Summary of Contents for NN-SG636 CTH
Page 9: ...SCHEMATIC DIAGRAM 4 3 ...
Page 29: ...6 2 DOOR PARTS D04 05 S03 D06 01 05 08 D03 D 1 2 3 4 5 6 7 8 ...
Page 30: ...6 3 CONTROL PANEL PARTS C 05 C18 S03 C01 C55 C 11 15 12 9 10 ...
Page 31: ...6 4 OVEN CAVITY PARTS 21 25 24 27 26 19 22 64 ...
Page 32: ...6 5 LATCH BOARD PARTS 28 29 29 30 32 ...
Page 33: ...INTERIOR PARTS 6 6 34 37 38 39 40 41 42 43 44 45 48 ...
Page 34: ...6 7 BASE PLATE PARTS 49 50 51 52 54 55 63 58 58 58 58 ...
Page 40: ......