9.5. SIMPLE WAY OF H.V. INVERTER/MAGNETRON TROUBLESHOOTING
Purpose:
Simple way
(3/23 seconds rule)
of identifying whether it’s Magnetron, Inverter or others.
Set-up:
The unit under question is connected through the Ammeter as shown below.
Procedure:
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this
procedure.
Power will:
Ammeter reading is:
To do:
Remedy:
Shut off in 23 seconds
after “Start”.
1. Between 0.5A and 1.0A.
Check and repair open magnetron circuit
CN703.
Open magnetron wiring between Inverter
and magnetron terminal.
2. Between 1.0A and 2.0A.
Check continuity of D702 in Inverter PCB.
1. D702 shorted
Replace
H.V.Inverter
(F606YBH20GP)
2. D702 is OK
Replace
magnetron
Shut off in 3 seconds
after “Start”.
1. Less than 0.5A
Check open circuit: Interlock Switch,
DPC, Power Relay, CN701 and CN702.
Replace
defective
component(s),
or
correct switch, cables and connectors.
9.6. How to check the semiconductors using an OHM meter
22
NN-SF564W