component test procedures.
3.2. Measurement of microwave output
The output power of the magnetron can be determined by performing IEC standard test
procedures. However,due to the complexity of IEC test procedures, it is recommended to test
the magnetron using the simple method outlined below.
Necessary Equipment:
*1 liter beaker *Glass thermometer / *Wrist watch or stopwatch
NOTE:
Check the line voltage under load.Low voltage will lower the
magnetron output. Take the temperature readings and heating time
as accurately as possible.
1. Fill the beaker with exactly one liter of tap water.Stir the water
using the thermometer and record the water’s temperature.
(recorded as T1).
2. Place the beaker on the center of glass tray. / Set the oven for
High power and heat it for exactly one minute.
3. Stir the water again and read the temperature of the water.
(recorded as T2).
4. The normal temperature rise at High power level for each model,
is as shown in table.
TABLE (1L-1min.test)
12
Summary of Contents for NN-S554WF
Page 3: ...3 ...
Page 4: ...4 ...
Page 5: ...5 ...
Page 6: ...1 SCHEMATIC DIAGRAM 1 1 NN S554MF WF 1 2 NN K593MF K574 K544WF 6 ...
Page 18: ...18 ...
Page 21: ...21 ...
Page 22: ...5 2 NN K593MF 22 ...
Page 23: ...23 ...
Page 24: ...5 3 NN K574MF WF NN K544WF 24 ...
Page 25: ...25 ...
Page 26: ...5 4 PARTS LIST 5 4 1 NN S554MF S554WF K574MF K574WF K544WF 26 ...
Page 33: ...3 ...
Page 34: ...4 ...
Page 35: ...5 ...
Page 36: ...1 SCHEMATIC DIAGRAM APH 2 SCHEMATIC DIAGRAM CPH 6 ...
Page 37: ...3 MEASUREMENTS AND ADJUSTMENTS 7 ...
Page 51: ...21 ...
Page 52: ...13 DIGITAL PROGRAMMER CIRCUIT NN T563SF APH NN T563SAF APH SCHEMATIC DIAGRAM 22 ...
Page 53: ...23 ...
Page 54: ...14 DIGITAL PROGRAMMER CIRCUIT NN S APH CPH SCHEMATIC DIAGRAM 24 ...
Page 55: ...25 ...
Page 56: ...15 DIGITAL PROGRAMMER CIRCUIT PARTS LIST 26 ...
Page 66: ...SCHEMATIC DIAGRAM APH 7 SCHEMATIC DIAGRAM APH ...
Page 67: ... 8 SCHEMATIC DIAGRAM CPH SCHEMATIC DIAGRAM CPH ...
Page 92: ... 33 ...
Page 93: ... 34 ...