1. Remove door C from door E by carefully pulling outward starting
from upper right hand corner using a flat blade screwdriver.
2. Separate door E from tabs on door A and remove door A.
3. Remove door screen B from door A.
4. Remove door key and door key spring.
5. Open Door E at the opening angle of approximately 10°(Note: The
door cannot be removed if the opening angle is greater than 10°).
6. Remove the door E from its hinges by pushing the door E upward
and out.
7. Replace other components.
NOTE:
Door alignment is crucial. If door is misaligned, apply pressure until
alignment is achieved.
NOTE:
After replacement of the defective component parts of the door,
reassemble, install, and perform microwave leakage test.
8.7. Turntable motor
1. Remove the motor cover by breaking off at the 4 spots indicated
18