CAUTION
1. Check grounding before checking for trouble.
2. Be careful of high voltage circuit.
3. Discharge high voltage capacitor.
4. When checking the continuity of the switches or the high voltage transformer,disconnect one lead wir
from these parts and then check continuity with the AC plug removed. To do otherwise may result in a
false reading or damage to your meter. / When disconnecting a plastic connector from a terminal, you
must hold the plastic connector instead of the lead wire and then disconnect it, otherwise lead wire m
be damaged or the connector cannot be removed.
5. Do not touch any parts of the circuitry on the digital programmer circuit, since static electric discharge
may damage this control panel. / Always touch yourself to ground while working on this panel to
discharge any static charge in your body.
6. 120V AC is present on the digital programmer circuit (Terminals of power relay's and primary circuit of
low voltage transformer). When troubleshooting, be cautious of possible electrical shock hazard.
First of all operate the microwave oven following the correct operating procedures in order to find the
exact cause of any trouble.
SYMPTOM
CAUSE
CORRECTIONS
1. Oven is dead.
1.
2.
3.
4.
Open or loose lead wire harness
Open thermal cutout (Magnetron)
Open low voltage transformer
Defective DPC
Check fan motor when thermal
cutout is defective.
Fuse is OK.
No display and no operation
at all.
2. No display and no operation
at all. / Fuse is blown.
1.
2.
Shorted lead wire harness
Defective primary latch switdh
(NOTE 1)
Check adjustment of primary,
secondary latch switch and sh
switch including door.
3. Defective short switch (NOTE 1)
4. Defective Inverter Power Supply (U)
Refer to component test procedure
Refer to Inverter PCB
Troubleshooting.
NOTE 1:
All of these switches must be replaced at the same time.
Check continuity of power relay B (RY-1)'s contacts (between 1 and 2
and if it has continuity, replace power relay B (RY-1) also.
3. Oven does not accept key
input(Program)
1.
2.
Key input is not insequence
Open or loose connection of
membrane key pad to DPC (Flat
cable)
Refer to operation procedure.
3. Shorted or open membrane key
board
4. Defective DPC
Refer to DPC troubleshooting.
4. Fan motor turn on when
oven is plugged in with door
closed.
3. Misadjustment or loose wiring of
secondary latch switch
Adjust door and latch switches
4. Defective secondary latch switch
35
Summary of Contents for NN-H264SFR
Page 35: ...reserved Unauthorized copying and distribution is a violation of law 2 ...
Page 36: ...3 ...
Page 37: ...4 ...
Page 38: ...5 ...
Page 40: ...3 CONTROL PANEL CPH 7 ...
Page 41: ...4 OPERATION AND DIGITAL PROGRAMMER CIRCUIT TEST PROCEDURE 4 1 To set clock 8 ...
Page 46: ...6 SCHEMATIC DIAGRAM CPH 13 ...
Page 67: ...13 TROUBLESHOOTING GUIDE 34 ...
Page 72: ...13 3 How to check the semiconductors using an OHM meter 14 EXPLODED VIEW AND PARTS LIST 39 ...
Page 80: ...20 DIGITAL PROGRAMMER CIRCUIT SCHEMATIC DIAGRAM 47 ...