9 TROUBLESHOOTING GUIDE
DANGER: HIGH VOLTAGES
1.
DO NOT RE-ADJUST PRESET CONTROL on the H.V.Inverter (U).
It is very dangerous to repair or adjust without proper test equipment
because this circuit generates very large current and high voltage. Operating a misaligned inverter circuit is dangerous.
2. Ensure proper grounding before troubleshooting.
3. Be careful of the high voltage circuitry, taking necessary precautions when troubleshooting.
4. Discharge high voltage remaining in the H.V.Inverter (U).
5. When checking the continuity of the switches or the H.V.Inverter, disconnect one lead wire from these parts and then check continuity with the
AC plug removed. Doing otherwise may result in a false reading or damage to your meter. When disconnecting a plastic connector from a
terminal, you must hold the plastic connector instead of the lead wire and then disconnect it, otherwise lead wire may be damaged or the
connector cannot be removed.
6. Do not touch any parts of the circuitry on the digital programmer circuit, since static electric discharge may damage this control panel. Always
touch ground while working on this panel to discharge any static charge in your body.
7. 120V AC is present on the digital programmer circuit (Terminals of power relay’s and primary circuit of Digital Programmer Circuit). When
troubleshooting, be cautious of possible electrical shock hazard.
Before troubleshooting, operate the microwave oven following the correct operating procedures in the instruction manual in order
to find the exact cause of any trouble, since operator error may be mistaken for the oven’s malfunction.
9.1. (Troubleshooting) Oven stops operation during cooking
SYMPTOM
CAUSE
CORRECTIONS
1.
Oven stops in 3 seconds
after
pressing [Start] pad.
No input AC is supplied to H.V.Inverter (U)
CN702 terminals
1. Interlock Switch
2. Power relay RL1
3. Loose lead wire connector CN701, CN702
4. H.V. Inverter (U)
Oven stops in 23 seconds
after
pressing [Start] pad.
H.V.Inverter (U) operates by the control signals
from DPC but magnetron is not oscillating
1. Magnetron
2. Loose lead wire connector CN703
3. H.V. Inverter (U)
2. No display and no operation at all.
Fuse is blown.
Most probably loose connection of connectors, or
door Interlock mechanism is not adjusted
properly
1. Align door, Door Interlock Switches
2. Loose wiring connectors
19
NN-GF574S / NN-GF574M
Summary of Contents for NN-GF574S
Page 2: ...2 NN GF574S NN GF574M ...
Page 3: ...3 NN GF574S NN GF574M ...
Page 5: ...1 FEATURE CHART 2 CONTROL PANEL 5 NN GF574S NN GF574M ...
Page 6: ...3 SCHEMATIC DIAGRAM 6 NN GF574S NN GF574M ...
Page 25: ...10 EXPLODED VIEW AND PARTS LIST 10 1 EXPLODED VIEW 25 NN GF574S NN GF574M ...
Page 31: ...11 DIGITAL PROGRAMMER CIRCUIT 11 1 SCHEMATIC DIAGRAM 31 NN GF574S NN GF574M ...
Page 32: ...32 NN GF574S NN GF574M ...