5.4. Inverter power supply (U)
DO NOT try to REPAIR H.V. Inverter power supply
(U).Replace complete H.V. Inverter(U) Unit.
WARNING: HIGH VOLTAGE
Test if failure codes H95, H97 or H98 appear when performing
the following procedure. It is recommended to use an AC line
input current ammeter for testing.
Test 1
1. With the oven unit’s AC power supply cord is unplugged
from the wall outlet, unplug the 2 pin H.V. connector CN703
from the magnetron tube.
2. Place 1 liter of water load into oven cavity.
3. Plug in the oven’s AC power supply cord into outlet.
4. Program DPC.
a. Press Timer / Clock button twice.
b. Press Start button once.
c. Press Power Level button once.
5. Program oven at High power for 1 minute and press [Start]
button.
a. After approximately 23 seconds, oven stops operating.
b. During
oven
operation,
the
input
current
is
approximately 0.5 to 1A. If both a and b are OK,
proceed to test 2.
INPUT CURRENT
FAILURE CODE
Unplug CN703
0.5 to 1A
Oven stops in 23
seconds after started.
Test 2
Continued from Test 1
1. Unplug the oven’s AC power supply cord from outlet.
2. Unplug 3 pin connector CN701. CN703 remains unplugged.
3. Plug in the oven’s AC power supply cord into outlet.
4. Program DPC.
a. Press Timer / Clock button twice.
b. Press Start button once.
c. Press Power Level button once.
5. Program oven at High power for 1 minute and press [Start]
button.
a. After approximately 3 seconds, oven stops operating.
b. During
oven
operation,
the
input
current
is
approximately 0.4A.
INPUT CURRENT
FAILURE CODE
Unplug CN701
0.4A
Oven stops in 3
seconds after started.
If both a and b check OK, the Inverter Power Supply (U) can be
determined to be OK.
5.5. Temperature thermistor
The thermistor that is attached to the magnetron detects the
temperature of the magnetron and will stop magnetron
operation when overheating is detected. A normal thermistor´s
resistance is 35K
Ω
to 110K
Ω
for an ambient temperature range
of 10-30 degree C.
If the resistance reading is out of the range stated here, the
thermistor is detective and must be replaced.
It is also possible to display thermistor level by taking the
following steps.
1. Program the DPC into TEST MODE (Plug-in oven
→
press
Timer / Clock button twice
→
press Start button once
→
press Power Level button once).
2. Program oven at Standing Time for 1 minute and press
[Start] button.
3. Press Power Level once, the thermistor level reading will
shown on the display.
The normal reading should be in the range of 16-240.
17
NN-GD693S
Summary of Contents for NN-GD693S
Page 2: ...2 NN GD693S ...
Page 3: ...3 NN GD693S ...
Page 5: ...1 SCHEMATIC DIAGRAM 5 NN GD693S ...
Page 27: ...8 7 How to check the semiconductors using an OHM meter 27 NN GD693S ...
Page 28: ...9 EXPLODED VIEW AND PARTS LIST 9 1 EXPLODED VIEW 28 NN GD693S ...
Page 30: ...Ref No Part No Part Name Description Pcs Set Remarks 65 F03349X90RP MENU LABEL 1 30 NN GD693S ...
Page 35: ...10 DIGITAL PROGRAMMER CIRCUIT 10 1 SCHEMATIC DIAGRAM 35 NN GD693S ...
Page 36: ...36 NN GD693S ...