6.2. Short switch & monitor
1. Unplug lead wires from Inverter Power Supply (U) primary
terminals.
2. Connect test probes of ohm meter to the disconnected leads
which were connected to Inverter Power Supply (U).
3. Test the continuity of short switch with door opened and closed
positions using lowest scale of the ohm meter. / Normal continuity
readings should be as follows.
6.3. Magnetron
Continuity checks can only indicate an open filament or a shorted magnetron. To diagnose for
an open filament or shorted magnetron.
1. Isolate magnetron from the circuit by disconnecting the leads.
2. A continuity check across magnetron filament terminals should
indicate one ohm or less.
3. A continuity check between each filament terminal and magnetron
case should read open.
6.4. Membrane key board (Membrane switch assembly)
Check continuity between switch terminals, by tapping an appropriate pad on the key board.
The contacts assignment of the respective pads on the key board is as shown in digital
programmer circuit.
6.5. Inverter power supply (U)
22
Summary of Contents for NN-GD566M
Page 4: ......
Page 5: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 37: ...3 ...
Page 38: ...4 ...
Page 39: ...5 ...
Page 40: ...1 SCHEMATIC DIAGRAM FOR GRILL MODELS 2 SCHEMATIC DIAGRAM FOR SOLO MODELS 6 ...
Page 72: ...38 ...
Page 76: ...42 ...
Page 77: ...17 DIGITAL PROGRAMMER CIRCUIT EPG MODELS SCHEMATIC DIAGRAM 43 ...
Page 78: ...44 ...
Page 79: ...18 DIGITAL PROGRAMMER CIRCUIT BPQ GPG MODELS PARTS LIST 45 ...