background image

Unlike many other appliances, the microwave oven is a high
voltage, high current device. It is free from danger in ordinary
use, though extreme care should be taken during repair.

CAUTION

Servicemen should remove their watches and rings
whenever working close to or replacing the magnetron.

5.1. Check the grounding

Do not operate on a two wire extension cord. The microwave
oven is designed to be grounded when used. It is imperative,
therefore, to ensure the appliance is properly grounded before
beginning repair work.

5.2. Inverter warnings

WARNING HIGH VOLTAGE AND HIGH TEMPERATURE

(HOT/LINE) OF THE INVERTER POWER SUPPLY (U)

The high voltage inverter power supply generates very high
voltage and current for the magnetron tube. Though it is
free from danger in ordinary use, extreme care should be
taken during repair.
The aluminum heat sink is also energized with high voltage
(HOT), do not touch when the AC input terminals are
energized. The power device Collector is directly connected
to the aluminum heat sink.
The aluminum heat sink may be HOT due to heat energy,
therefore, extreme care should be taken during servicing.

WARNING FOR INVERTER POWER SUPPLY (U)

GROUNDING

Check the high voltage inverter power supply circuit
grounding. The high voltage inverter power supply circuit
board must have a proper chassis ground. The inverter
grounding bracket must be connected to the chassis. If the
inverter board is not grounded it will expose the user to very
high voltages and cause extreme DANGER! Be sure that
the inverter circuit is properly grounded via the inverter
earth bracket.

WARNING

DISCHARGE

THE

HIGH

VOLATGE

CAPACITORS

For about 30 seconds after the oven is turned off, an
electric charge remains in the high voltage capacitors of the
inverter power supply circuit board.
When replacing or checking parts, remove the power plug
from the outlet and short the inverter output terminal of the
magnetron filament terminals to the chassis ground with an
insulated handle screwdriver to discharge. Please be sure
to contact the chassis ground side first and then short to the
output terminal.

WARNING

There is high voltage present with high current capabilities
in the circuits of the primary and secondary windings, choke
coil and heat sink of the inverter. It is extremely dangerous
to work on or near these circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit
including the filament voltage of the magnetron.

WARNING

Never touch any circuit wiring with your hand or with an
insulated tool during operation.

5 CAUTIONS TO BE OBSERVED WHEN

TROUBLESHOOTING

8

NN-GD371S / NN-GD361M / NN-GD351W

Summary of Contents for NN-GD371S

Page 1: ...Panasonic Home Appliances Microwave Oven Shanghai Co Ltd 2011 NN GD371S NN GD361M NN GD351W BPQ U K EPG Continental Europe WPG Switzerland Microwave Oven ORDER NO PHAMOS1106061CE...

Page 2: ...2 NN GD371S NN GD361M NN GD351W...

Page 3: ...3 NN GD371S NN GD361M NN GD351W...

Page 4: ...ter Power Supply 14 7 COMPONENT TEST PROCEDURE 16 7 1 Primary Secondary Latch Switch interlocks Power Relay RY1 16 7 2 Short switch monitor 16 7 3 Magnetron 16 7 4 DC fan motor 16 7 5 Inverter power s...

Page 5: ...1 FEATURE CHART 2 CONTROL PANEL 5 NN GD371S NN GD361M NN GD351W...

Page 6: ...3 SCHEMATIC DIAGRAM 6 NN GD371S NN GD361M NN GD351W...

Page 7: ...ve doubler voltage rectifier circuit consisting of the H V diodes and capacitors generates the necessary 4 000V DC needed for the magnetron 5 Output power of the magnetron tube is always monitored by...

Page 8: ...ircuit grounding The high voltage inverter power supply circuit board must have a proper chassis ground The inverter grounding bracket must be connected to the chassis If the inverter board is not gro...

Page 9: ...1 After repair or replacement of parts make sure that the screws of the oven etc are neither loose nor missing Microwave energy might leak if screws are not properly tightened 2 Make sure that all el...

Page 10: ...2 screws holding the magnetron NOTE After replacement of the magnetron tighten mounting screws properly making sure there is no gap between the waveguide and the magnetron to prevent microwave leakage...

Page 11: ...elays NOTE Do not use a soldering iron or desoldering tool of more than 30 watts on D P C contacts 2 With all the terminal pins cleaned and separated from D P C contacts remove the defective transform...

Page 12: ...emble it properly and adjustment so as to prevent an excessive microwave leakage Adjustment of the door assembly Refer page 18 7 Place the hole of hinge A into the door s upper hinge pin 8 Use your le...

Page 13: ...emoving the motor cover be sure that cut portions are properly trimmed off or bent to the inside so that no sharp edges will be exposed to outside 2 Disconnect 2 lead wires connected to the turntable...

Page 14: ...y pulling it out from the cavity left side 6 8 H V Inverter Power Supply 1 Disconnect 2 high voltage lead wires from magnetron filament terminals 2 Unplug connector CN701 CN702 from H V Inverter board...

Page 15: ...6 Remove 2 screws holding H V inverter on the inverter bracket 15 NN GD371S NN GD361M NN GD351W...

Page 16: ...itor 1 Unplug lead wires from Inverter Power Supply U primary terminals 2 Connect test probes of ohm meter to the disconnected leads which were connected to Inverter Power Supply U 3 Test the continui...

Page 17: ...supply cord into outlet 4 Program DPC a Press Clock button once b Press Delay Stand button once c Press Start button once d Press Micro Power button once 5 Program oven at High power for 1 minute and...

Page 18: ...wing the component test procedures 8 2 Measurement of microwave output The output power of the magnetron can be determined by performing IEC standard test procedures However due to the complexity of I...

Page 19: ...control panel Always touch ground while working on this panel to discharge any static charge in your body 7 230 240V AC is present on the digital programmer circuit Terminals of power relay s and prim...

Page 20: ...cause magnetron to have lower output and or be intermittent 3 Defective high voltage component H V Inverter Power Supply U Magnetron Check high voltage component according to component test procedure...

Page 21: ...program the DPC into TEST MODE press Clock button once press Delay Stand button once Press Start button once press Micro Power button once Program unit for operation H95 H97 H98 H99 appears in display...

Page 22: ...dure Power will Ammeter reading is To do Remedy Shut off in 23 seconds after Start 1 Between 0 5A and 1 0A Check and repair open magnetron circuit Open magnetron wiring between Inverter and magnetron...

Page 23: ...C C702 ZCWF4305N851 FILM CAPACITOR 1 3 F 250VDC DB701 Z0FBBQ000006 RECTIFIER BRIDGE 1 L701 Z5020W100AP CHOKE COIL 1 R702 Z0CM562JA002 SAND BAR RESISTOR 1 T701 Z609ABA00GP TRANSFORMER 1 INCLUDING D701...

Page 24: ...10 EXPLODED VIEW AND PARTS LIST 10 1 EXPLODED VIEW 24 NN GD371S NN GD361M NN GD351W...

Page 25: ...DARY LATCH SWITCH 21 Z61785U30XN SHORT SWITCH 1 SHORT SWITCH 22 Z2M236 M36R MAGNETRON 1 23 Z606YBA00GP H V INVERTER U 1 24 Z6585BA00EP INVERTER BRACKET 1 25 Z66629W40HP GROUNDING PLATE 1 27 Z62306V60B...

Page 26: ...Q E3 Z800LBB10SEP ESCUTCHEON BASE U 1 GD371S EPG GD371S WPG E4 Z891PBA00SEP DOOR OPENING BUTTON U 1 GD371S E5 Z8256BA00EP DOOR OPENING LEVER 1 E6 Z80375K00AP COOK BUTTON SPRING 1 E7 Z9009BA00EP GROUND...

Page 27: ...6 Z80375K00AP COOK BUTTON SPRING 1 E28 Z803G9M60SBP POP OUT DIAL U 1 GD361M E28 Z803G9M60HBP POP OUT DIAL U 1 GD351W E29 Z8018BA00EP DIAL SUPPORT 1 E30 Z8298BA10SBP BUTTON 1 GD361M E30 Z8298BA10HBP BU...

Page 28: ...Z30189V00XP DOOR KEY A 1 D3 Z302KBA00EP DOOR E U 1 D4 Z30215G10XN DOOR KEY SPRING 1 D5 Z30859V00XP DOOR C 1 D6 Z3145BB10EP DOOR SCREEN A 1 D8 Z302ABB10SEP DOOR A U 1 GD371S D8 Z302ABB30SEP DOOR A U 1...

Page 29: ...10 5 WIRING MATERIALS Ref No Part No Part Name Description Pcs Set Remarks W1 Z030ABB10BP LEAD WIRE HARNESS 1 W2 Z030EBA00EP H V LEAD WIRE 1 29 NN GD371S NN GD361M NN GD351W...

Page 30: ...E PAPER 1 GD361M P2 Z0102BB40HEP PACKING CASE PAPER 1 GD351W P3 Z01049V00XP UPPER FILLER 1 P4 Z01059V00XP LOWER FILLER 1 P5 Z01068100XN P E BAG 1 P6 Z01075G10XN DOOR SHEET 1 P7 Z0601BA00EP COOKING TRA...

Page 31: ...11 DIGITAL PROGRAMMER CIRCUIT 11 1 SCHEMATIC DIAGRAM 31 NN GD371S NN GD361M NN GD351W...

Page 32: ...32 NN GD371S NN GD361M NN GD351W 06 11 S BB1 S BB3 S BB4 Printed in China...