5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and then
gradually returns to
Normal:
∞
Normal: Continuity.
Abnormal:
∞
Normal:
∞
Abnormal: Continuity.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament
10M ohms.
*
*
Summary of Contents for NN-CT651MMKPQ
Page 9: ...4 3 SCHEMATIC DIAGRAM RY3 RY4 RY5 RY1 RY2 15A ...
Page 31: ...6 2 DOOR PARTS 1 2 3 5 6 7 8 9 4 ...
Page 32: ...6 3 CONTROL PANEL PARTS 10 11 12 13 ...
Page 33: ...INTERIOR PARTS 6 4 18 19 20 23 25 26 31 32 33 28 30 71 72 65 64 29 27 21 22 24 85 ...
Page 34: ...6 5 36 LATCH BOARD PARTS 41 34 35 42 37 37 38 39 84 ...
Page 35: ...6 6 OVEN CAVITY PARTS 44 45 46 47 48 49 50 51 52 R00 43 ...
Page 36: ...6 7 BASE PLATE PARTS 53 54 55 56 57 59 60 61 ...
Page 40: ......