TROUBLE SHOOTING GUIDE
CONDITION
CHECK POINT
CAUSE
REMEDY
No steam or poor
steaming force
(perform
STEAM
TEST
)
A. Check if Temperature selector
dial is set at steam zoon( " "
to " "). [ red areaon
Temperature Selector Dial ]
B. Remove the Water tank, fill
if with water and set the Steam/
Dry selector in steam position
while tank is held horizontally.
C. Check temperature control
range (See
TEMPERATURE
TEST METHOD
).
D. Check for clogged steam
vents on the Soleplate.
A-1. Too low temperature may
cause poor discharge of steam
or water dropping.
B-1. If water does not drip con-
stantly from the bottom
opening, it may be clogged.
C-1. Refer to Item A-1.
D-1. Clogged steam vents may
cause poor steaming.
Set Temperature selector dial
at steam zoon( " " to " ").
Clean opening or replace Tank
if necessary.
Reset the adjusting screw or
refer to
T
E
MPERATURE
TEST METHOD
.
Clean steam vents.
Water leaks from
steam vents
E. Refer to item A.
F. Refer to item C.
Water leaks from
Water Tank
housing
G. Check that Steam/Dry selector
is set in Dry position.
G-1. Cracked or damaged Water
tank cause water leak.
Replace the Water tank.
Follow the collect instructions
for carrying and storing the iron.
If Soleplate is damged it will
have to be replaced.
H-1. Improper care for the iron
after each use and/or high
mineral content water.
H. Check if white particles come
out while steaming.
White powder like
particles come
out from steam
vents while stea-
ming
(Perform
STEAM
TEST
)
Replace the Spray assembly.
Clean the nozzie.
I -1. The Spray mist button is
defective.
J-1. The Spray nozzie is clogged.
I. Check if the Spray mist button
operates correctly.
J. Check if there is any clogging
of nozzie.
No spray mist
Replace the Jet of steam
button.
Put in the Ball.
Adjust the temperature or
replace Soleplate.
K -1. The Jet of steam button is
defective.
L -1. The Ball is not put in.
M-1.Temperature setting is too low.
K. Check if the Jet of steam button
operates correctly.
L. Check if the Ball is put in.
M. Temperature setting is too low.
Jet of Steam is no
put out
A. Check if Temperature selector
dial is set at steam zoon( " "
to " "). [ red areaon
Temperature Selector Dial ]
B. Remove the Water tank, fill
if with water and set the Steam/
Dry selector in steam position
while tank is held horizontally.
C. Check temperature control
range (See
TEMPERATURE
TEST METHOD
).
D. Check for clogged steam
vents on the Soleplate.
―
8
―