background image

TROUBLE SHOOTING GUIDE

CONDITION

CHECK POINT

CAUSE

REMEDY

No steam or poor
steaming force

(perform 

STEAM

 TEST

)

A. Check if Temperature selector
    dial is set at steam zoon( "      " 
    to "      "). [ red areaon
    Temperature Selector Dial ]

B. Remove the Water tank, fill
    if with water and set the Steam/
    Dry selector in steam position
    while tank is held horizontally.

C. Check temperature control
    range (See 

TEMPERATURE

    TEST METHOD

).

D. Check for clogged steam
    vents on the Soleplate.

A-1. Too low temperature may
       cause poor discharge of steam
       or water dropping.

B-1. If water does not drip con-
       stantly from the bottom
       opening, it may be clogged.

C-1. Refer to Item A-1.

D-1. Clogged steam vents may
       cause poor steaming.

Set Temperature selector dial
at steam zoon( "      " to "      ").

Clean opening or replace Tank
if necessary.

Reset the adjusting screw or
refer to 

T

MPERATURE

TEST METHOD

.

Clean steam vents.

Water leaks from
steam vents

E. Refer to item A.
F. Refer to item C.

Water leaks from
Water Tank
housing

G. Check that Steam/Dry selector
     is set in Dry position.

G-1. Cracked or damaged Water
        tank cause water leak.

Replace the Water tank.

Follow the collect instructions
for carrying and storing the iron.

If Soleplate is damged it will
have to be replaced.

H-1. Improper care for the iron
       after each use and/or high
       mineral content water.

H. Check if white particles come
     out while steaming. 

White powder like
particles come
out from steam
vents while stea-
ming
(Perform 

STEAM

 TEST

)

Replace the Spray assembly.

Clean the nozzie.

I -1. The Spray mist button is
       defective.
J-1. The Spray nozzie is clogged.

I.  Check if the Spray mist button
    operates correctly.
J. Check if there is any clogging
    of nozzie.

No spray mist

Replace the Jet of steam
button.
Put in the Ball.
Adjust the temperature or
replace Soleplate.

K -1. The Jet of steam button is
        defective.
L -1. The Ball is not put in.
M-1.Temperature setting is too low.

K. Check if the Jet of steam button
     operates correctly.
L. Check if the Ball is put in.
M. Temperature setting is too low.

Jet of Steam is no
put out

A. Check if Temperature selector
    dial is set at steam zoon( "      " 
    to "      "). [ red areaon
    Temperature Selector Dial ]

B. Remove the Water tank, fill
    if with water and set the Steam/
    Dry selector in steam position
    while tank is held horizontally.

C. Check temperature control
    range (See 

TEMPERATURE

    TEST METHOD

).

D. Check for clogged steam
    vents on the Soleplate.

 8 