How to Operate
Programming
'"i. .•-s s „•... ,r% ..!.
— DO NOT OPEN THE DOOR —
The display window MUST be blank before programming can begin. If any indicator light is
illuminated in the digital Display Window; close the door, press
STOP/RESET
Pad and
wait 1 minute until the Display goes blank,
A. Programming Memory Pads for Single Stage Heating:
Example: To program 30 seconds at Medium Power for Memory Pad Number 5
1
.
PROG
•Press the
PROG
Pad.
NOTE:
•If no
PROG
Indicator appeared
on display, “Program Lock” should
be cancelled. (See page 14.)
•Do not keep pressing
PROG
Pad
for more than 30 seconds, or a
false failure code may result.
•Press the Memory Pad 5.
The pad number and the previously
selected time and power level will
appear in the display.
Display Window
Display Window
^PQG___
3.
4.
POWER
LEVEL
Tm i
•The pad number and Stage
Heating Indicator will appear
in the display again.
•Press the
Power Level
Selector
Pad 2 times. The Memory Pad
display will go out.
•Press Memory Pads 3 and 0.
;
00
5.
PROG
•Press the
PROG
Pad again. You
have completed programming
the selected Memory Pad for
single stage heating and double
heating time for multiple portion
heating automatically.
•2 seconds later, the time and
power level setting for single
stage will appear in the display.
•2 seconds later, Double Quantity
Heating Indicator and then the
double heating time will appear
in the display.
•2 seconds later, the display
will go blank.
Memory Pad 5 is now programmed
for heating - 30 seconds at MED Power
n
U
n
u
n n
u u
- 1 1 -
Summary of Contents for NE1064T - COMMERCIAL MICROWAVE
Page 18: ...Notes 18 ...