7 Test Mode
7.1.
Component test procedure
7.1.1.
High voltage transformer
1. Remove connections from the transformer terminals and
check continuity.
2. Normal (cold) resistance readings should be as follows:
Secondary winding Approx. 80
Ω
-120
Ω
Filament winding Approx. 0
Ω
Primary winding Approx. 0
Ω
-3
Ω
7.1.2.
High voltage capacitor
1. Check continuity of capacitor with meter on highest OHM
scale.
2. A normal capacitor will show continuity for a short time,
and then indicate 9M
Ω
once the capacitor is charged.
3. A shorted capacitor will show continuous continuity.
4. An open capacitor will show constant 9M
Ω
.
5. Resistance between each terminal and chassis should be
infinite.
7.1.3.
Magnetron
Continuity checks can only indicate an open filament or a
shorted magnetron. To diagnose for an open filament or
shorted magnetron.
1. Isolate magnetron from the circuit by disconnecting the
leads.
2. A continuity check across magnetron filament terminals
should indicate one ohm or less.
3. A continuity check between each filament terminal and
magnetron case should read open.
Summary of Contents for NE-1252
Page 2: ...2 1 Safety Precautions ...
Page 5: ...5 4 Location of Controls and Components 4 1 Outline diagram ...
Page 16: ...16 8 2 Troubleshooting guide ...
Page 24: ...24 ...
Page 25: ...25 11 Schematic Diagram 11 1 NE 12521 NE 12523 ...
Page 26: ...26 11 2 NE 1252 ...
Page 27: ...27 11 3 NE 17521 NE 17523 NE 17723 NE 21521 NE 21523 ...
Page 28: ...28 11 4 NE 1752 NE 1772 NE 2152 ...
Page 29: ...29 12 Exploded View and Replacement Parts List 12 1 Exploded view and parts list ...