Procedure
Figure
3.Remove the two lead wire holders and the one
connector to remove the 3D sensor.
After remove the upper board,
1.Push the one pawl to outward as shown in figure,
and pull
the water level detector upward.
2.Remove the connector and sub hose A from the
water level detector.
3.Remove the water level detector.
After remove the upper board,
1.Remove the four screws mounting the detergent
case A.
2.Remove the two screws and the two pawls
mounting the pressure hose case.
3.loosen the nut from the feed valve unit by using
the spanner.
-27-
4
Replacement of
the water level
detector
5
Replacement of
the feed valve
NA-16VX1/16VG1/14VA1