11.6. Electronic Pressure Sensor (EPS)
Electromagnetic field occurs due to movement of pressur-
ized membrane. The spring moves vertically by nucleus
due to electromagnetic field. The water level is regulated
according to the frequency changes of the spring by elec-
tronic card.
Testing component
Push the door lock slider with screwdriver.
Select the 1st program and start the machine.
Unplug power cable when as soon as water intake finishes
and drum begins to rotate.
Check the water level inside the drum with ruler. It should
be 10 cm ±1.