Auto Tuning Functions
5-2
5.1 Automatic adjusting function
The figure below shows outline of automatic adjusting function of MINAS A6 Multi series.
Real-time auto tuning
Estimates the load characteristics based on the motor velocity and torque command, and automatically
sets up the basic gain related to position and velocity control, based on estimated inertia. Also estimates
the friction torque at the same time and adds the estimated value to the torque command to shorten
positioning settling time.
Adaptive filter
Estimates the resonance frequency based on the motor velocity and removes the frequency
components from torque command to prevent resonant oscillation.
5.1.1 Real-time auto tuning
The system estimates the load characteristics in real time, and automatically performs basic gain setting
and friction compensation by referring to stiffness parameter.
For the 2 degrees of freedom control mode, refer to section "5.1.3Real-time auto tuning
(Two-degree-of-freedom control mode standard type)", "5.1.4 Real-time auto tuning
(Two-degree-of-freedom control mode synchronization type)".
Applicable range
This function operates under the following conditions.
Real-time auto-tuning condition:
Control Mode
Specific Real-time auto tuning mode is selected according to the currently active control mode. For details, refer to
the description of Pr 0.02 Real-time auto tuning setup.
Others
Should be in servo-on condition
Parameters except for controls such as torque limit setup, are correctly set, assuring that the motor can run
smoothly.
Summary of Contents for MINAS A6 Series
Page 10: ...Table of contents x Blank page...
Page 11: ...1 Introduction...
Page 26: ...Introduction 1 16 Blank page...
Page 27: ...2 Interface Specifications...
Page 46: ...Interface Specifications 2 20 Blank page...
Page 47: ...3 Front Panel Specifications...
Page 57: ...4 Basic Functions...
Page 85: ...5 Auto Tuning Functions...
Page 151: ...6 Application Functions...
Page 185: ...7 Protective Functions...
Page 224: ...Protective Functions 7 40 Blank page...
Page 225: ...8 Advanced Safety Functions...
Page 230: ...Advanced Safety Functions 8 6 When test pulse is used Duplex safety input Safety input...
Page 245: ...9 List of Parameters...
Page 281: ...10 Timing Chart...
Page 290: ...Timing Chart 10 10 Blank page...
Page 291: ...11 Power Supply Module...