12.2 Error Detection for CD/Changer block
TOP
PREVIOUS
NEXT
@
TOP
PREVIOUS
NEXT
No.
Error
Error
Display
Problem Condition
1 REST SW detection error
F15
CD dose not function./This error occurs when the Optical Pick Up REST SW (S701) is
not detected within the specified time (about 8 seconds)
2 CD tray opens automatically
F16
CLAMP switch (S4) NG (Check& Replace)
3 Does not startup when/“TUNE/TIME ADJ^” button
is/pressed
F17
BOTTOM switch (S5) NG (Check& Replace)
4 Transmission error between CD/servo LSI and
micon
F26
CD does not function./This error occurs when the POWER is ON for the CD block and
an error is detected after the transmission has started.
5 Startup fails even when you insert CD or the
selected disc tray does not open
F27
Tray 1 detect switch or Tray 2 detect switch NG (Check& Replace)
6 Cannot insert CD
F28
Tray 1 detect switch NG (Check& Replace)
7 Cannot eject CD
F29
Check if Disc is stuck. Tray 2 detect switch NG (Confirm& Replace)
8 CD Tray closes
H15
CD disc tray detect switch NG (S3) (Check& Replace)