background image

8 TROUBLE SHOOTING GUIDE

CONDITION

CHECKPOINT

METHOD OF INSPECTION

CAUSE / REMEDY

Motor fails to rotate
(no noise is heard at all)

Power supply cord

Check power supply cord
continuity.

If there is no continuity, replace
the cord reel unit.

Fuse
(Plug for UK only)

Check plug fuse continuity.

If there is no continuity, replace
the cord reel unit.

Fuse of P.C.B. Ass’y
(250V, 12 A)

Check fuse continuity.

If there is no continuity, replace
P.C.B. Ass’y.

Motor continuity

Check motor continuity between
carbon brush holder tabs.

If there is no continuity, replace
the carbon brush or motor.

Check the motor performance. Apply a voltage directly to both

sides of the motor terminal to see if
the motor performs as specified.

If

the

motor

fails

to

perform,

replace it with new one.

ON/OFF Switch

Check

continuity

across

switch

connections

If there is no continuity, replace
Switch or P.C.B. Ass’y.

Triac (Inside of P.C.B.)

Check if the triac is in open circuit. If it is in open circuit, replace

P.C.B.Ass’y.

P.C.B. Ass’y

Check the internal parts for
anything unusual. (burn-out, melt-
down, etc.)

If anything is found unusual,
replace the P.C.B. assembly with
new one.

Motor runs but there is no suction Hose or Suction inlet

Check if there is any blockage in
the hose or suction inlet.

If there is any blockage, remove it.

Dust compartment / Filters

Check if dust compartment is full
or there is dust accumulated in the
filters.

If dust compartment is full, empty
it.If the filters are dirt of dust,
clean them out or replace.

Noise or vibration

Motor fan

Check dust accumulated in motor
fan (it could happen if the vacuum
cleaner has been used without
central filter).

If there is dust accumulated in the
motor fan, replace the motor and
check filter condition. (never try to
dismantle the motor fan)

Motor does not change power
(runs always at full speed)

Control Axis

Check if the potentiometer is
short-circuited.

If it is short-circuited, replace
power control circuit.

P.C.B. Ass’y

Check if power control circuit is
short-circuited.

If it is short-circuited, replace it.

Motor runs irregularly

control Axis

Check possible bad contact of
P.C.B. Ass’y.

If there is bad contact, replace
P.C.B. Ass’y.

13

MC-E8021 / MC-E8021K / MC-E8023 / MC-E8023K / MC-E8024 / MC-E8024K

Summary of Contents for MC-E8021

Page 1: ...Electric Industrial Co Ltd All rights reserved Unauthorized copying and distribution is a violation of law MC E8021 MC E8021K MC E8023 MC E8023K MC E8024 MC E8024K Destination Europe Vacuum Cleaner ORDER NO ECD0502001C2 ...

Page 2: ...out Fig 2 There are 2 latches on the front side of Ornamental plate Please remove it by pulling strongly from the back side 3 REPLACEMENT OF MAIN PARTS IMPORTANT Before replacing any part always DISCONNECT THE CLEANER FROM THE ELECTRICITY SUPPLY 3 1 MOTOR 4 MC E8021 MC E8021K MC E8023 MC E8023K MC E8024 MC E8024K ...

Page 3: ...m the front side Important When reassembling the Switch Pedal please place ControlAxis and Switch Pedal in the right place as they can fit 4 Lift up cord reel unit and remove the two lead wires provided with quick connect terminal from the contact springs Fig 4 5 Take out motor unit and remove motor cover Fig 5 5 MC E8021 MC E8021K MC E8023 MC E8023K MC E8024 MC E8024K ...

Page 4: ...nect terminal from the motor tabs 3 Remove the two screws from the carbon brush holder and take it out Fig 8 4 Replace the carbon brush unit with a new one and reinstall it refastening with the screw 5 Connect the lead wires according to the schematic diagram and reassemble the motor unit 6 Re install motor unit cord reel ass y into their lodging and reassemble the remaining parts in the reverse o...

Page 5: ...y into place and reassemble the remaining parts in the reverse order If the cord is damaged replace the cord reel unit with new one Reason If the cord has worn out the cord reel spring or the cord s electric welded zone may also be adversely affected 3 5 BRAKE LEVER UNIT 1 Remove upper body and cord reel assembly as explained previously in paragraph 3 1 Motor points 1 5 2 To change the brake lever...

Page 6: ... cut off with weld it 6 Replace P C B Ass y with a new one and control Axis 7 Connect the two lead wires provided with quick connect terminal to the PCB tabs and reinstall power control circuit in its support Fig 17 Note Before reinstalling the circuit make sure the lead wires are correctly positioned in the cover slots 8 Place back the motor unit Connect the lead wires according to the schematic ...

Page 7: ...internal parts for anything unusual burn out melt down etc If anything is found unusual replace the P C B assembly with new one Motor runs but there is no suction Hose or Suction inlet Check if there is any blockage in the hose or suction inlet If there is any blockage remove it Dust compartment Filters Check if dust compartment is full or there is dust accumulated in the filters If dust compartme...

Page 8: ...009 1 Language Polish Czech Romanian Hungarian Bulgarian and Ukrainian MC E8021 E8023 6 Instruction Book AMC01Z XL00E 1 Language German Dutch French Swedish Norwegian Danish Spanish English Portuguese Italian Finish and Greek MC E8021 E8023 E8024 7 Instruction Sheet AMC09Z XL008 1 Language English UK version MC E8021K E8023K E8024K 7 Instruction Sheet AMC09Z XL009 1 Language Polish Czech Romanian ...