EC Directives

The EC directives apply to all such electronic products as those having specific functions 

and directly sold to general consumers in EU countries.  These products are required to 

meet the EU unified standards and to be furnished with CE marking.

Our brushless motor meet the EC Directives for Low Voltage Equipment so that the 

machine or equipment comprising our AC servo can meet relevant EC Directives.

EMC Directives

Our brushless motor can meet EMC Directives and related standards.  However, to meet 

these requirements, the systems must be limited with respect to configuration and other 

aspects, e.g. the installation and some special wiring conditions must be met.  This means 

that in some cases machines and equipment comprising our servo systems may not satisfy 

the requirements for wiring and grounding conditions specified by the EMC Directives.  

Therefore, conformance to the EMC Directives (especially the requirements for emission 

noise and noise terminal voltage) should be examined based on the final products that 

include our system.

Applicable standard

Applicable standard

Installation 

condition

UL

UL508

 

Standard for electric converter equipment

Class I equipment

Pollution degree 2 

SCCR

 *1

CE

EN61800-5-1 

Adjustable speed electrical power drive systems. 

 

– Safety requirements. Electrical, thermal and energy

EN61800-3 

Adjustable speed electrical power drive systems.

 

– EMC requirements and specific test methods

EN55011 

Radio  interference  wave  characteristics  of  industrial,   

 

scientific,  and medical high-frequency equipment   

EN61000-6-2 

Standards for immunity in industrial environment

  

(EMC directive)

Overvoltage 

category II

Class I equipment

Pollution degree 2 

Group 1

Class A

Category Ⅲ

2nd enviroment

KC

Korea Radio Law 

*2

  Class A Instrument 

 

(commercial broadcast communications equipment)

*1  SCCR: Symmetrical current 5,000 Arms, Max. 240 V

 

Motor over-temperature protection is not provided. 

 

Motor over-load-temperature protection shall be provided at the final installation upon 

required by the NEC (National Electric Code).

*2  Information related to the Korea Radio Law

 

This brushless amplifier is a Class A commercial broadcasting radio wave generator 

not designed for home use. The user and dealer should be aware of this fact.

 

Brushless Amplifier

Conformance to EC directive and UL standard

Conformance to EC directive and UL standard

Configuration of peripheral equipment

Power 

supply

 100 V system: Single phase 100 V to 120 V ± 10 %, 50/60 Hz

  200 V system: Single phase/3-phase 200 V to 240 V ± 10 %, 50/60 Hz

 Use the equipment under the environment of overvoltage category II specified by 

IEC60664-1.

 In order to obtain overvoltage category III, insert a transformer conforming to EN 

standard or IEC standard to the input of brushless motor.

 Use an electric wire size suitable to EN60204-1.

MCCB

(breaker)

Fuse

Be sure to connect a specified MCCB certified by IEC standard and UL, or a fuse 

certified by UL between power supply and noise filter. Observance of this condition 

allows conformance with UL508C (file No. E164620) .

Noise

 filter

When installing one noise filter at the power supply for more than one brushless 

motor used, contact the manufacturer of noise filter. 

Surge 

absorber

Install a surge absorber on the primary side of noise filter. However, in performing 

the voltage resistance test of machine and equipment, be sure to remove the surge 

absorber; otherwise, the surge absorber may be ruptured.

Grounding

Be sure to connect the grounding Terminal of brushless amplifier and protective 

grounding wire (PE) of system for preventing electric shock. Do not tighten the 

grounding wires together but connect them individually. 

Wiring of peripheral equipment

Brushless

amplifier

Brushless

motor

Surge 

absorber

Noise filter

Protection ground

(PE)

ground

Power

supply

Ferrite core (Noise filter for signal line)

option DV0P1460 (*Qty.

: 

4 ) (part No.: ZCAT3035-1330/TDK Corp.)

Reactor core (8 turn or more)

Cabtyre cable

* The ferrite core should insert one or more 

  pieces in an electric wire, respectively. 

Molded Case

Circuit Breaker

(MCCB)

or Fuse

List of compatible peripheral equipment

Part name

Optional part 

number 

(option)

Manufacturer's

part No.

Qty.

Manufacturer

Noise filter(single phase)

DV0P4170

SUP-EK5-ER-6

1

OKAYA ELECTRIC IND. 

CO., LTD.

Noise filter(3-phase)

DV0PM20042 3SUP-HU10-ER-6

1

Surge absorber(single phase)

DV0P4190

R

A

V-781BWZ-4

1

Surge absorber(3-phase)

DV0P1450

R

A

V-781BXZ-4

1

Noise filter for control signals

DV0P1460

ZCAT3035-1330

4

TDK Co.Ltd,.

Reactor core

RJ8035

— Konno Kogyosho CO.,Ltd.

Recommended circuit breaker

   Made by Sensata Technologies Japan Limited:

       Type IELH-1-11-63-5A-M (single phase)     Type IELH-1-111-63-5A-M (3-phase)

       (Rated current 5A, cutoff characteristics DELAY63)

       • Recommended cutoff characteristics: DELAY61-63

Summary of Contents for MBEK011BCV

Page 1: ... after reading and read as necessary Be sure to give this Instruction manual to an end user Label of safety precaution is affixed to the product If you are the first user of this product please be sure to read the instruction Manual Overall from our Web Site Web address of Panasonic Corporation http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html This product image is 200 W type o...

Page 2: ...urrent protection earth leakage breaker over temperature protecter and emergency stop device must be installed The failure could result in electric shocks injuries or fire Transportation wiring and checking must be performed with power source turned off and after making sure that there is no risk of electric shock The failure could result in electric shocks or injuries Do not subject the product t...

Page 3: ...ght this product Checking the model of Amplifier and Motor This amplifier is designed for use in combination with a motor to be specified by us Check a name of series rated output voltage specifications you wish to use You must not use any other combinations than those listed below Standard Voltage Out put Amplifier Type Applicable Motor Single phase AC100 to 120 V 50 W MBEK5A1BCV MBMS5AZBL 100 W ...

Page 4: ...otor in corrosive atmosphere such as hydrogen sulfide sulfurous acid chlorine ammonia sulfur gas chloride gas sulfide acid alkali and salt in the atmosphere of combustible gas or in the vicinity of flammables 3 Place not exposed to grinding liquid oil mist iron powder and cutting particle 4 Well ventilated place with little moisture oil or inundation and place far from heat source such as a furnac...

Page 5: ...supply outside of equipment from MCCB use an electric wire of 1 6 mm diameter 2 0 mm2 or more both for main circuit and grounding Apply grounding class D 100 Ω or below for grounding Do not tighten the ground wires together but connect them individually Fastening torque of earth screws to be 0 49 to 0 98 N m For details of parameters refer to the Instruction Manual Overall For the wiring of commun...

Page 6: ...ation Connection of digital key pad of an option is possible digital key pad connecting cable of an option DV0P383 is required The terminal number of a modular jack is the following figure 8 1 Refer to operation manual Overall for the correspondence procedure of RS485 1 Do not connect anything 2 5 V DC5 V power supply for digital key pad 3 SOT Interface for digital key pad or PANATERM for BL 4 SIN...

Page 7: ...fier Conformance to EC directive and UL standard Conformance to EC directive and UL standard Configuration of peripheral equipment Power supply 100 V system Single phase 100 V to 120 V 10 50 60 Hz 200 V system Single phase 3 phase 200 V to 240 V 10 50 60 Hz Use the equipment under the environment of overvoltage category II specified by IEC60664 1 In order to obtain overvoltage category III insert ...

Page 8: ...void inputting a supply voltage which significantly exceeds the rated range to the power supply of this product Failure to heed this caution may result in damage to the internal parts causing smoking and or a fire and other trouble Item Specifications Model name Brushless amplifier MBEK 5A1BCV MBEK 5A5BCV MBEK 011BCV MBEK 015BCV MBEK 021BCV MBEK 025BCV MBEK 045BCV MBEK 083BCV Brushless motor MBMS5...

Page 9: ... can be downloaded from the following web site http industrial panasonic com ww i_e 25000 motor_fa_e motor_fa_e html Pursuant to at the directive 2004 108 EC article 9 2 Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Hamburg F R Germany 7 1 1 Morofuku Daito Osaka 574 0044 Japan Phone 81 72 871 1212 For your records The model number and serial number of this product ...

Reviews: