![Panasonic MADDT1207 Technical Reference Download Page 15](http://html.mh-extra.com/html/panasonic/maddt1207/maddt1207_technical-reference_275156015.webp)
– B15 –
– B14 –
3. System Configuration and Wiring
Connection
Driver Applicable
motor Voltage
Rated
output
Required
Power
(at the rated
load)
Noise
filter for
signal
Noise
filter
Surge
absorber
Magnetic
contactor
Cable
diameter
(main circuit)
Cable
diameter
(control circuit)
MADD
MBDD
MCDD
MDDD
MEDD
MSMD
MQMA
MSMD
MQMA
MAMA
MSMD
MQMA
MSMD
MQMA
MAMA
MQMA
MSMD
MAMA
MFMA
MHMA
MAMA
MDMA
MHMA
MGMA
MSMA
MHMA
MDMA
MSMA
MFMA
MDMA
MSMA
MHMA
MFMA
Single
phase,
100V
Single
phase,
200V
Single
phase,
100V
Single
phase,
200V
Single
phase,
100V
Single/
3- phase,
200V
Single/
3- phase,
200V
3- phase,
200V
50W
to 100W
100W
50W
to 200W
100W
200W
100W
200W
400W
200W
400W
750W
400W
500W
750W
1.0kW
900W
1.0kW
1.5kW
2.0kW
2.5kW
approx.
0.4kVA
approx.
0.4kVA
approx.
0.5kVA
approx.
0.3kVA
approx.
0.5kVA
approx.
0.3kVA
approx.
0.5kVA
approx.
0.9kVA
approx.
0.5kVA
approx.
0.9kVA
approx.
1.3kVA
approx.
0.9kVA
approx.
1.1kVA
approx.
1.6kVA
approx.
1.8kVA
approx.
1.8kVA
approx.
1.8kVA
approx.
2.3kVA
approx.
3.3kVA
approx.
3.8kVA
Circuit
breaker
(rated
current)
10A
15A
20A
30A
DV0P4170
DV0P4180
DV0P4220
Connection to exclusive connector
DV0P4190
DV0P1450
DV0P1460
BMFT61041N
(3P+1a)
BMFT61542N
(3P+1a)
BMFT61041N
(3P+1a)
BMFT61542N
(3P+1a)
BMFT61541N
(3P+1a)
BMFT61542N
(3P+1a)
BMFT61842N
(3P+1a)
BMF6352N
(3P+2a2b)
0.75 to
2.0mm
2
AWG
14 to 18
2.0mm
2
AWG14
2.0mm
2
AWG14
3.5mm
2
AWG12
0.75mm
2
AWG18
Terminal
block
M5
11.0 or
smaller
ø5.3
Connection
Driver Applicable
motor Voltage
Rated
output
Required
Power
(at the rated
load)
Noise
filter for
signal
Noise
filter
Surge
absorber
Magnetic
contactor
Cable
diameter
(main circuit)
Cable
diameter
(control circuit)
Circuit
breaker
(rated
current)
MFDD
MGMA
MDMA
MHMA
MSMA
MGMA
MDMA
MHMA
MSMA
MFMA
MGMA
MDMA
MHMA
MSMA
3- phase,
200V
2.0kW
3.0kW
4.0kW
4.5kW
5.0kW
approx.
3.8kVA
approx.
4.5kVA
approx.
6kVA
approx.
6.8kVA
approx.
7.5kVA
approx.
7.5kVA
50A DV0P3410 DV0P1450 DV0P1460
BMF6352N
(3P+2a2b)
BMF6652N
(3P+2a2b)
3.5mm
2
AWG12
5.3mm
2
AWG10
0.75mm
2
AWG18
Terminal
block
M5
11.0 or
smaller
ø5.3
Driver and List of Applicable Peripheral Equipments
• Select a single and 3-phase common specifications according to the power source.
• Manufacturer of circuit breaker and magnetic contactor : Matsushita Electric Works.
To comply to EC Directives, install a circuit breaker between the power and the noise
filter without fail, and the circuit breaker should conform to IEC Standards and UL
recognized (Listed and marked).
5000Arms, 240V is the maximum capacity to be delivered to the circuit of 750W or
larger model when the maximum current value of the circuit breaker is limited to 20A.
• For details of noise filters, refer to P.B42, "Noise Filter".
<Remarks>
• Select and use the circuit breaker and noise filter with matching capacity to those of
the power source, considering the load conditions as well.
• Terminal block and protective earth terminal
Use a copper conductor cable with temperature rating of 60˚C or higher.
Protective earth terminal is M4 for A to D-frame, and M5 for E and F-frame.
Larger tightening torque of the screw than the max. value (M4 : 1.2 N
•
m, M5 : 2.0 N
•
m)
may damage the terminal block.
• Earth cable diameter should be 2.0mm
2
(AWG14) or larger for 50W to 2.0kW model,
and 3.5mm
2
(AWG12) or larger for 2.5kW to 4.0kW, and 5.3mm
2
(AWG10) or larger
for 4.5kW to 5kW model.
• Use the attached exclusive connectors for A to D-frame, and maintain the peeled off
length of 8 to 9mm.
• Tightening torque of the screws for connector (CN X5) for the connection to the host
to be 0.3 to 0.35 N
•
m. Larger tightening torque than these may damage the connector
at the driver side.