20
Important notice about "Error Code List"
1) About "*" indication:
The third digit from the left is different as follows.
+.In case of 0 (example: 18
0
01000)
When the third digit from the left shows "0", this error occurred under the condition of INITIAL SETTINGS has been completed.
It means that this error is occurred basically at user side.
+.In case of 8 (example: 18
8
01000)
When the third digit from the left shows "8", this error occurred under the condition of INITIAL SETTINGS has been released.
(Example; Factory assembling-line before unit shipment, Service mode etc.)
It means that this error is occurred at service side.
2) About "?" indication: ("18*0 0?01" to "18*0 0?50"):
The third digit from the right shows one of the hexadecimal ("0" to "F") character.
4. How to exit from Error Code display mode:
Simply, turn the power off. (Since Error code display mode is executed under the condition of temporary cancellation of "INITIAL
SETTINGS", it wake up with normal condition when turn off the power.)
Note:
The error code can not be initialized.
Summary of Contents for LUMIX DMC-TZ60EB
Page 27: ...27 9 Disassembly and Assembly Instructions 9 1 Disassembly Flow Chart 9 2 P C B Location...
Page 29: ...29 9 3 1 Removal of the Rear Case Unit Fig D1 9 3 2 Removal of the Operation P C B Unit Fig D2...
Page 30: ...30 9 3 3 Removal of the LCD Unit Fig D3 9 3 4 Removal of the Frame Plate Fig D4...
Page 31: ...31 Fig D5 9 3 5 Removal of the Jack Door Unit PCB Spacer Fig D6...
Page 32: ...32 9 3 6 Removal of the NFC P C B Fig D7 9 3 7 Removal of the Lens Unit Fig D8...
Page 33: ...33 9 3 8 Removal of the Main P C B Fig D9 9 3 9 Removal of the Top Case Unit Fig D10...
Page 34: ...34 9 3 10 Removal of the LVF Unit Top P C B Unit Fig D11 Fig D12...
Page 52: ...52...