2. Put the insulation tube onto the lead part of Resistor (ERG5SJ102:
1k /5W).
(an equivalent type of resistor may be used.)
3. Put the resistor between both terminals of capacitor on FLASH
TOP C.B.A. for approx. 5 seconds.
4. After discharging, confirm that the capacitor voltage is lower than
10V using a voltmeter.
6.4. CLEANING LENS AND LCD PANEL
Do not touch the surface of lens and LCD Panel with your hand.
When cleaning the lens, use air-Blower to blow off the dust.
When cleaning the LCD Panel, dampen the lens cleaning paper with lens cleaner, and the gently
wipe the their surface.
Note:
A lens cleaning paper and lens cleaner are available at local camera shops and market place.
7. ADJUSTMENT PROCEDURES
Even if the MAIN C.B.A. is replaced as a unit, it must be achieved the adjustment and factory
setting. The adjustment in this unit is separated two types as shown below.
The adjustment instruction is available at "Software download" on the CS-Web from AVC" web-
site in "TSN System".
1. Main unit adjustment: All adjustments except for LCD adjustment.
This unit mounts the adjustment software for main unit, it
wouldn’t need the connection between the PC and this unit with
USB cable.
2. LCD adjustment: Adjustment for LCD.
16
PDF created with pdfFactory Pro trial version
Summary of Contents for LUMIX DMC-LS1EB
Page 2: ...SPECIFICATIONS 2 PDF created with pdfFactory Pro trial version www pdffactory com ...
Page 3: ...3 PDF created with pdfFactory Pro trial version www pdffactory com ...
Page 20: ...20 PDF created with pdfFactory Pro trial version www pdffactory com ...
Page 27: ...Fig D2 27 PDF created with pdfFactory Pro trial version www pdffactory com ...
Page 30: ...Fig D6 Fig D7 30 PDF created with pdfFactory Pro trial version www pdffactory com ...
Page 40: ...40 PDF created with pdfFactory Pro trial version www pdffactory com ...
Page 44: ...44 PDF created with pdfFactory Pro trial version www pdffactory com ...
Page 53: ......
Page 69: ......