22
7.2.
When Replacing the Main P.C.B.
After replacing the MAIN P.C.B., be sure to achieve adjustment.
The service software is available at “TSN Website”. To download, click on “Support Information from NWBG/VDBG-AVC”.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing FLASH P.C.B.)
1. Be sure to discharge the E.capacitor on FLASH P.C.B..
Refer to “HOW TO DISCHARGE THE E.CAPACITOR ON FLASH P.C.B.”.
The E.capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH P.C.B..
3. DO NOT allow other parts to touch the high voltage circuit on FLASH P.C.B..
No.
Parts No.
Connection
Form
1
VFK1906
PS9001 (MAIN) - PP8001 (FLASH)
20PIN B to B
2
VFK1953
FP9005 (MAIN) - LENS UNIT
40PIN 0.5 FFC