8
3 Service Navigation
3.1.
Introduction
This service manual contains technical information, which allow service personnel’s to understand and service this model.
Please place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
3.2.
Service Navigation
3.2.1.
About lens block
• The image sensor (MOS SENSOR) unit which are connected to the lens unit with 3 screws. These screws are locked with the
screw locking glue, after performing the Optical tilt adjustment.
During servicing, if one of MOS SENSOR fixing screws are loosened, the Optical tilt adjustment must be performed.
(About the Optical tilt adjustment, refer to the “9.3.2 Adjustment Specifications” for details.)
NOTE:
• It is necessary to use the “DSC_Tilt” software to allow the “Optical tilt adjustment”.
• The Adjustment software “DSC_Tilt” is available at “TSN Website”. To download, click on “Support Information from NWBG/
VDBG-AVC”.
3.2.2.
About VENUS FHD(IC6001) [Located on the Main P.C.B.]:
• The VENUS FHD (IC6001) consists of two IC chips, which are fixed together with solder.
(The so called, “Package On Package” type IC.)
NOTE:
• During servicing, do not press down hard on the surface of IC6001.
Summary of Contents for Lumix DMC-FZ100P
Page 14: ...14 4 Specifications...
Page 27: ...27 8 3 1 Removal of the Rear Case Unit Fig D1 Fig D2...
Page 30: ...30 Fig D10 8 3 8 Removal of the AF MF Flex Unit Fig D11 Fig D12...
Page 31: ...31 8 3 9 Removal of the Flash P C B Fig D13 Fig D14...
Page 33: ...33 Fig D17 Fig D18 8 3 12 Removal of the Speaker Fig D19...
Page 34: ...34 Fig D20 8 3 13 Removal of the LCD Unit and Hinge P C B Fig D21...
Page 40: ...40 8 4 6 Removal of the 3rd Lens Frame Unit and 4th Lens Frame Unit...
Page 47: ...47...
Page 61: ...S 12...