30
8.4.
Lens Disassembly Procedure
Precaution:
1. Do not remove the MOS sensor unit when disassembling
or re-assembling the lens in order to maintain it clean.
The screw fitting the MOS sensor unit to the master
flange unit is fixed by the screw locking glue with the
adjustment of the installation angle of the MOS sensor
unit against the lens (optical tilt adjustment) finished.
When remove it, refer to item "8.6.".
2. Keep dust or dirt away from the lens.
To remove dirt or dust from the lens, blow with dry air.
3. Do not touch the lens surface.
4. Use lens cleaning KIT (VFK1900BK).
5. Apply grease (RFKZ0472) as shown on "THE APPLICA-
TION OF GREASE METHOD" in the figure.
6. The fixed frame unit, drive frame unit, penetration cam
frame unit, cam frame unit and direct frame should be
replaced as a unit.
8.4.1.
Removal of the Zoom Motor and
Lens FPC P.C.B. Unit
1. Remove the Connector.
2. Remove the 1 lock (A).
3. Remove the 7 solders (A).
4. Unscrew the 2 screws (A).
5. Remove the zoom motor to the direction of arrow (1).
6. Remove the lock (A) and lock (B).
7. Unscrew the 1 screw (B).
8. Remove the photo sensor.
9. Remove the 4 solders (B).
10. Remove the lens FPC P.C.B. unit to the direction of arrow
(2).
Summary of Contents for Lumix DMC-FX700P
Page 13: ...13 4 Specifications...
Page 25: ...25 Fig D2 8 3 2 Removal of the Sub Operation FPC Unit PCB Frame Fig D3...
Page 26: ...26 8 3 3 Removal of the LCD Unit Fig D4 8 3 4 Removal of the Top Operation Unit Fig D5...
Page 27: ...27 8 3 5 Removal of the Flash Top P C B and Speaker Fig D6 Fig D7...
Page 44: ...44...
Page 55: ...S 9...