16
•
5. How to read the error code:
One error code is displayed for 8 bit, the contents of error codes is indicated the table as shown below.
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4 bits Low 4 bits
Check point (Lower)
LENS
Lens drive
OIS
18*0
1000
PSD (X) error. Hall element (X axis) position detect error in OIS unit.
OIS Unit
2000
PSD (Y) error. Hall element (Y axis) position detect error in OIS unit.
OIS Unit
3000
GYRO (X) error. Gyro (IC7101: X axis) detect error on Main P.C.B..
IC7101 (Gyro element) or IC6001 (VENUS 4)
4000
GYRO (Y) error. Gyro (IC7101: Y axis) detect error on Main P.C.B..
IC7101 (Gyro element) or IC6001 (VENUS 4)
5000
MREF error (Reference voltage error).
IC9101 (LENS drive) or IC6001 (VENUS 4)
6000
Drive voltage (X) error.
VENUS 4 AD value error, LENS Unit, LENS flex breaks etc.
7000
Drive voltage (Y) error.
VENUS 4 AD value error, LENS Unit, LENS flex breaks etc.
C.B./Zoom
0010
HP Low detect error. (HP ENC. detects always low.
(Fully retracted condition.))
Zoom motor, ABS ENC., and/or circuit failure. Zoom deadlock (Exit side).
0020
HP High detect error. (HP ENC detects always High. (Exit condition.))
Zoom motor, ABS ENC., and/or circuit failure. Zoom deadlock
(Retract side).
0030
0040
0050
Zoom ENC. detect error.(No signal is supplied from Encoder located on
Zoom Motor.)
Zoom motor, ABS ENC., and/or circuit failure. Zoom deadlock.
Focus
0001
HP Low detect error (Focus encoder always Low detect error).
FP9002-(3) signal line or IC6001 (VENUS 4)
0002
HP High detect error (Focus encoder always High detect error).
FP9002-(2) signal line or IC6001 (VENUS 4)
Lens
18*1
0000
Power ON time out error.
Lens drive system
18*2
0000
Power OFF time out error.
Lens drive system
Adj.History
OIS
19*0
2000
OIS adj. Yaw direction amplitude error (small)
3000
OIS adj. Pitch direction amplitude error (small)
4000
OIS adj. Yaw direction amplitude error (large)
5000
OIS adj. Pitch direction amplitude error (large)
6000
OIS adj. MREF error
7000
OIS adj. time out error
8000
OIS adj. Yaw direction off set error
9000
OIS adj. Pitch direction off set error
A000
OIS adj. Yaw direction gain error
B000
OIS adj. Pitch direction gain error
C000
OIS adj. Yaw direction position sensor error
D000
OIS adj. Pitch direction position sensor error
E000
OIS adj. other error
Summary of Contents for Lumix DMC-FX500E
Page 12: ...12 4 Specifications ...
Page 13: ...13 5 Location of Controls and Components ...
Page 14: ...14 ...
Page 20: ...20 8 Disassembly and Assembly Instructions 8 1 Disassembly Flow Chart 8 2 PCB Location ...
Page 22: ...22 8 3 2 Removal of the Front Case Unit Fig D2 8 3 3 Removal of the Top Operation Unit Fig D3 ...
Page 24: ...24 8 3 6 Removal of the LCD Unit Fig D7 8 3 7 Removal of the Lens Unit Fig D8 ...