10
3.4.2.
INITIAL SETTINGS:
When you replace the Main PCB, be sure to perform the initial settings after achieving the adjustment by ordering the following pro-
cedure in accordance with model suffix of the unit.
1. IMPORTANT NOTICE:
Before proceeding Initial settings, be sure to read the following CAUTIONS.
2. PROCEDURES:
• Precautions: Proceed the picture back up from the unit. (Refer to above "CAUTION 2")
• Preparation. Set the Recording mode to "Normal Picture Mode".
Set the [REC]/[PLAYBACK] selector switch to "[REC] (Red camera mark)".
Turn on the power and then press the [MODE] button.
Select the "NORMAL PICTURE MODE" using "[UP] / [DOWN] of Cursor button".
Press [MENU/SET] button, then turn the power off.
•
Step 1. The temporary cancellation of initial setting:
Set the [REC]/[PLAYBACK] selector switch to “[ REC ] (Red camera mark)”.
While keep pressing [ E.ZOOM ] and “[ UP ] of Cursor buttons” simultaneously, turn the Power on.
•
Step 2. The cancellation of initial setting:
Set the [REC]/[PLAYBACK] selector switch to “[ PALYBACK ]”.
Press [ E.ZOOM ] and “[ UP ] of Cursor buttons” simultaneously, then turn the Power off.
•
Step 3. Turn the Power on:
Set the [REC]/[PLAYBACK] selector switch to “[ REC ] (Red camera mark)”, and then turn the Power on.
•
Step 4. Display the INITIAL SETTING:
While keep pressing [ MENU ] and “[ RIGHT ] of Cursor buttons” simultaneously, turn the Power off.