S-2
S2. Voltage Chart
S2.1. Main P.C.B.
Note) Indicated voltage values are the standard values for the unit measured by the DC electronic circuit tester (high-impedance) with the chassis taken as standard.
Therefore, there may exist some errors in the voltage values, depending on the internal impedance of the DC circuit tester.
REF No.
PIN No. POWER ON
IC1001
1
4.9
IC1001
2
6.4
IC1001
3
5.2
IC1001
4
6.4
IC1001
5
2.2
IC1001
6
0
IC1001
7
1.7
IC1001
8
6.4
IC1001
9
6.9
IC1001
10
6.9
IC1001
11
9.7
IC1001
12
5.2
IC1001
13
4.3
IC1001
14
0
IC1001
15
4.4
IC1001
16
6.4
IC1001
17
0
IC1001
18
4.1
IC1001
19
5.2
IC1001
20
1.2
IC1001
21
1.4
IC1001
22
1.4
IC1001
23
1.4
IC1001
24
0
IC1001
25
0
IC1001
26
0
IC1001
27
1.2
IC1001
28
0
IC1001
29
6.4
IC1001
30
5
IC1001
31
9.7
IC1001
32
4.1
IC1001
33
1.4
IC1001
34
0
IC1001
35
1.7
IC1001
36
1.3
IC1001
37
0.8
IC1001
38
4.9
IC1001
39
6.9
IC1001
40
6.4
IC1001
41
6.9
IC1001
42
3.9
IC1001
43
0
IC1001
44
5.5
IC1210
1
4.9
IC1210
2
0
IC1210
3
4.5
IC1210
4
5.2
IC3002
1
4.8
IC3002
2
0
IC3002
3
4.3
IC3002
4
4.9
Q1040
1
0
Q1040
2
0
Q1040
3
2.6
Q1040
4
0
Q1040
5
0
Q1040
6
4.5
Q1050
1
5.2
Q1050
2
6.4
Q1050
3
-9.2
Q1050
4
0
Q1050
5
0
Q1050
6
0
QR1101
E
0
QR1101
C
0
REF No.
PIN No. POWER ON
QR1101
B
6.9